100W Single Output with Battery Charger(UPS Function)
PSC-100 series
Features :
Universal AC input / Full range
5"x3" compact size
Optional L-Bracket and cover (PSC-100x-C, x=A,B)
Protections: Short circuit / Overload / Over voltage
Battery low protection / Battery polarity protection by fuse
Relay contact signal output for AC OK and Battery Low
Cooling by free air convection
100% full load burn-in test
2 years warranty
SPECIFICATION
MODEL
PSC-100A
PSC-100B
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
13.8V
4.75A
0 ~ 7A
100W
13.8V
2.5A
27.6V
27.6V
1.25A
--------
RATED CURRENT
CURRENT RANGE
RATED POWER
2.4A
--------
0 ~ 3.5A
100.74W
100mVp-p
CH1: 24 ~ 29V
1.0%
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 1.0%
--------
--------
OUTPUT
CH1: 12 ~ 15V
--------
--------
--------
--------
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
0.5%
--------
0.5%
0.5%
--------
0.5%
Note.5 2400ms, 30ms/230VAC
2400ms, 30ms/115VAC at full load
40ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
86%
16ms/115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
88%
INPUT
2A/115VAC
1.2A/230VAC
COLD START 35A/115VAC
<1mA / 240VAC
70A/230VAC
LEAKAGE CURRENT
105 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:14.49 ~ 18.63V
CH1:28.98 ~ 37.26V
PROTECTION
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
10 0.5V
20 1V
BATTERY CUT OFF
Relay contact output, ON : AC OK ; OFF : AC Fail ; Max. rating : 30V / 1A
Note.6
AC OK
ALARM
Relay contact output, OFF : Battery OK ; ON : Battery Low ; Max. rating : 30V / 1A
FUNCTION
BATTERY LOW
Battery low voltage : < 11V
Battery low voltage : < 22V
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0~50 ) on CH1 output
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
417.6K hrs min. MIL-HDBK-217F (25
)
PCB:127*76.2*31mm (L*W*H) ; with optional CASE:130*85*37mm (L*W*H)
OTHERS
NOTE
DIMENSION
PACKING
PCB:0.23Kg; 63pcs/15.5Kg/1.35CUFT ; with optional CASE:0.44Kg;32pcs/15Kg/0.64CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Please refer to suggest application (2) (4) in page 3.
7. Heat sink HS2,HS3 can not be shorted.
8. Heat sink HS2,HS3 must have safety isolation distance from system case.
File Name:PSC-100-SPEC 2011-03-03