6VJ1_11

型号:

6VJ1_11

描述:

电源输入模块,带电压选择和融合[ Power Entry Module with Voltage Selection and Fusing ]

品牌:

MACOM[ Tyco Electronics ]

页数:

3 页

PDF大小:

278 K

Catalog: 1654001  
Issue Date: 06.2011  
Corcom Product Guide  
Power Entry Module with Voltage Selection and Fusing  
J Series  
Front View, all models  
UL Recognized  
CSA Certified  
6J4  
6HJ4  
J Series  
Specifications  
• Power entry module with North American style  
3AG fuse holder  
Maximum leakage current each Line to Ground:  
6HJ4 or  
non–filtered  
5 A  
6J4 Models  
• 2 or 4 voltage selection  
• Compact snap-in design  
@250 VAC 50 Hz:  
500 A  
Hipot rating (one minute):  
Line to Ground:  
Line to Line:  
• Two element circuit provides basic  
EMI attenuation  
1550 VAC  
1450 VDC  
• Available with minimal leakage current suitable  
for medical applications (HJ models)  
Operating Voltage:  
suffix - 1 or - 4 models:  
suffix - 2 models:  
100, 120, 220 or 240VAC  
115 or 230 VAC  
• Also available without filter (VJ models)  
Operating Frequency:  
Rated Current:  
50/60 Hz  
6A  
Ordering Information  
Required Fuse:  
.25 x 1.25  
(not included)  
6 H J 4 -4  
Available Voltage Selections  
1 - Four (non–filtered versions)  
2 – Two  
4 or blank – Four (filtered versions)  
Filtered Indicator  
1 – Non–filtered  
4 – Filtered  
Available Part Numbers  
J Series  
Non–filtered models  
6VJ1  
6VJ1-2  
Filter Type  
H – Medical  
V – Non-filtered  
Blank – general purpose  
General Purpose Filters  
6J4  
6J4-2  
Medical Filters  
Current Rating  
6A  
6HJ4-4  
6HJ4-2  
172  
Dimensions are in inches and millimeters unless otherwise specified. Values in italics  
are metric equivalents. Dimensions are shown for reference purposes only.  
Specifications subject to change.  
For email, phone or live chat, please go to  
te.com/help  
corcom.com  
Catalog: 1654001  
Issue Date: 06.2011  
Corcom Product Guide  
Power Entry Module with Voltage Selection and Fusing (continued)  
J Series  
Electrical Schematics  
6VJ1 & 6VJ1-2  
Accessories  
GA400:NEMA 5-15P to IEC 60320-1 C-13 line cord  
Note 3  
220V  
240V  
120V  
100V  
Note 2  
Hot  
A
B
J
A
B
C
Power On/Off  
20V  
R
S
Off  
100V  
H
On  
Pilot  
light  
Ground  
Neutral  
D
K
D
E
120V  
M
Note 2  
L
F
Note 1  
JA302: 2 Voltage Select Card  
Comes standard with 6VJ1-2, 6J4-2 and  
Transformer  
N
P
primary  
6J4 & 6J4-2  
6HJ4-2  
Note 3  
220V  
240V  
120V  
100V  
JA304  
: 4 Voltage Select Card  
A
B
C
A
B
C
20V  
Power On-O!  
O!  
Comes standard with 6VJ1, 6J4 and 6HJ4-4  
Hot  
100V  
3
JA403: Mounting clips for .105 - .125” panels  
Ground  
Pilot  
light  
On  
D
E
D
E
120V  
JA410-419: Equipment Rating Labels  
Neutral  
J
H
F
F
Note 1  
Self-adhesive, available in multiples of 40  
Specify part number  
Transformer  
primary  
6HJ4-4 & 6J4-2  
2.330  
Note 3  
220V  
240V  
120V  
(230V)  
100/120V (115V) 220/240V  
Line V. + 5 - 10%  
48-440 - 50 VA Max.  
100V  
.210  
Fuse  
500mA  
250mA  
A
A
20V  
Power On-O!  
O!  
B
C
B
Hot  
100V  
A
C
B
C
Ground  
Pilot  
light  
On  
D
E
D
E
A
VA  
max.  
25  
50  
100  
200  
250  
B
Fuse  
C
120V  
Fuse  
Neutral  
J
H
F
F
Part No.  
JA410  
JA411  
100/120 (115) 220/240 (230)  
Note 1  
Transformer  
primary  
250 mA  
500 mA  
1A  
2A  
2.5A  
3A  
125 mA  
250 mA  
500 mA  
1A  
  
  
  
  
  
  
JA412  
JA413  
JA414  
JA415  
JA416  
JA417  
JA418  
JA419  
Voltage Selection  
1.25A  
1.5A  
2A  
2.5A  
3A  
300  
400  
500  
600  
Assortment  
4 A  
5A  
6A  
JA410-JA418: 40 labels of one part number  
JA419: 5 each of JA410 - JA418 (45 labels)  
Open cover door and slide fuse-pull lever to left.  
Select operating voltage by orienting voltage selec-  
tion card with the desired voltage on top left side.  
Push card firmly into module slot. Slide fuse-pull lever  
to right into normal position and re-insert fuse into  
holders.  
JA500: Voltage Selector Card Extractor Tool  
Use caution in selecting correct fuse value.  
173  
Dimensions are in inches and millimeters unless otherwise specified. Values in italics  
are metric equivalents. Dimensions are shown for reference purposes only.  
Specifications subject to change.  
For email, phone or live chat, please go to  
te.com/help  
corcom.com  
Catalog: 1654001  
Issue Date: 06.2011  
Corcom Product Guide  
Power Entry Module with Voltage Selection and Fusing (continued)  
J Series  
Case Styles  
Case Dimensions  
A
  
B
  
C
  
D
  
Part No.  
Non-filtered Models  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
6VJ1, 6VJ1-2  
C
6J4, 6J4-2,  
6HJ4-4, 6HJ4-2  
D
B
A
  
   
   
  
  
Performance Data  
Typical Insertion Loss  
Measured in closed 50 Ohm system  
6J4  
db  
6HJ4  
db  
Filtered Models  
100  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
60  
50  
40  
30  
20  
10  
C
D
B
A
0
0
0.1  
1
10  
30  
0.1  
1
10  
30  
Frequency in MHz  
Frequency in MHz  
  
   
  
   
  
Common Mode / Asymmetrical (L-G)  
Differential Mode / Symmetrical (L-L)  
Recommended Panel Cutouts  
Door Open Position  
Minimum Insertion Loss  
Measured in closed 50 Ohm system  
1.063* 1.17  
27.0 29.7  
Common Mode / Asymmetrical (Line to Ground)  
    
Bezel  
Clearance  
2.60*  
* .003 .076]  
   
  
   
  
  
  
  
  
  
  
  
  
66.0  
2.68  
68.1  
3.00  
76.2  
  
  
  
  
  
  
  
  
  
  
174  
Dimensions are in inches and millimeters unless otherwise specified. Values in italics  
are metric equivalents. Dimensions are shown for reference purposes only.  
Specifications subject to change.  
For email, phone or live chat, please go to  
te.com/help  
corcom.com  
厂商 型号 描述 页数 下载

TE

6VJ1 电压选择和融合连接器与通用申请UL544医疗保健设备可选RFI电源线滤波器[ Voltage Selecting and Fused Connector with Optional RFI Power Line Filter for General Purpose Applications for UL544 Health Care Equipment ] 4 页

TE

6VJ1-2 电压选择和融合连接器与通用申请UL544医疗保健设备可选RFI电源线滤波器[ Voltage Selecting and Fused Connector with Optional RFI Power Line Filter for General Purpose Applications for UL544 Health Care Equipment ] 4 页

TE

6VJ4 电压选择和融合连接器与通用申请UL544医疗保健设备可选RFI电源线滤波器[ Voltage Selecting and Fused Connector with Optional RFI Power Line Filter for General Purpose Applications for UL544 Health Care Equipment ] 4 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.243097s