EYP2BH133

型号:

EYP2BH133

描述:

温度保险丝( TCO )[ Thermal Cutoffs (TCO) ]

品牌:

PANASONIC[ PANASONIC ]

页数:

8 页

PDF大小:

178 K

Thermal Cutoffs (TCO)  
Thermal Cutoffs (TCO)/  
Thermal-Links  
Series:  
EYP  
N
Series:  
Series:  
Series:  
Series:  
Series:  
F
E
H
ML  
MU  
Features  
Small and Insulation Type  
TCO is compact and insulated, featuring quick temperature response, and mountable in a small space without  
insulation or protection.  
High Reliability  
TCO opens reliably when the equipment becomes abnormal, and is not resettable.  
Solid Structure  
Unique formed lead provides reliable TCO connection and provides easy assembly handling. (Axial lead type only)  
Non-Cadomium Alloy  
Thin Type  
Thickness is less than 1 mm. Available for spot welding.(ML and MU series)  
Approved Safety Standards  
Recommended Applications  
PS  
Transformers, Solenoids, Ventilation fans, Electric  
fans, Small electric motors, Driers, Gas home appliances,  
Fluorescent lights, Electric shavers, Adaptors, Heating  
devices, ICs, Batteries, etc. The TCO can also be used  
for overheating protection.  
UL  
E
(Japan)  
(U.S.A.)  
: Approved by JET  
: E60271  
CSA (Canada) : LR67163  
VDE (Germany) : 4811. 6-1171-२२२२  
BEAB (U.K.)  
: C२२२२  
CCC (China)  
: २२२२२२२२२२२२२२२२  
See Ratings in details.  
Construction  
Axial lead type (N, F and E series)  
Radial lead type (H series)  
Sealant (Epoxy resin)  
Fusible alloy  
Fusible alloy  
Insulating  
case(Ceramic)  
Special formed  
lead wire  
(Tin plating copper)  
Special resin  
Insulating  
case (Ceramic)  
(Flux)  
Special resin  
(Flux)  
Thin type (MTand MS series)  
Insulating film  
Fusible alloy  
Terminal (Ni)  
Lead wire  
(Tin plating copper)  
Sealant  
(Epoxy resin)  
Special resin  
(Flux)  
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
Mar. 2005  
Thermal Cutoffs (TCO)  
Ratings  
N series  
Maximum Temp.  
Limit (°C)  
Electrical  
Rating  
Approved Safety  
Rated  
Maximum  
Operating  
Temp.  
5  
Standards  
Type No. of  
Approved  
Standards  
Functioning  
Temp.  
Holding  
Temp.  
(°C)  
Functioning  
2  
4  
Part No.  
RoHS  
1  
3  
Temp.  
UL,VDE,  
BEAB  
CCC  
(°C)  
AC/ Amp. Volt.  
DC (A)  
PS  
E
(°C)  
(°C)  
CSA  
150  
UL  
CSA VDE BEAB CCC  
(V)  
52  
60  
45  
56  
62  
47  
65  
75  
55  
76  
80  
65  
76  
80  
65  
90  
94  
80  
92  
96  
82  
99  
103  
80  
105  
110  
80  
120  
120  
90  
56  
60  
50  
60  
65  
52  
70  
76  
60  
86  
90  
74  
86  
90  
74  
105  
105  
94  
108  
108  
96  
115  
115  
90  
115  
120  
90  
AC  
AC  
DC  
AC  
AC  
DC  
AC  
AC  
DC  
AC  
AC  
DC  
AC  
AC  
DC  
AC  
AC  
DC  
AC  
AC  
DC  
AC  
AC  
DC  
AC  
AC  
DC  
AC  
AC  
DC  
3
2
4
3
2
4
3
2
4
3
2
5
3
2
5
3
2
5
3
2
5
3
2
6
3
2
6
3
2
6
125  
250  
50  
125  
250  
50  
125  
250  
50  
125  
250  
50  
125  
250  
50  
125  
250  
50  
125  
250  
50  
125  
250  
50  
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
EYP2BN082  
EYP2BN088  
EYP2BN098  
EYP2BN109  
EYP2BN110  
EYP2BN124  
EYP2BN126  
EYP2BN135  
EYP2BN143  
EYP2BN163  
N082  
N088  
N098  
N109  
N110  
N124  
N126  
N135  
N143  
N163  
86  
82 2  
88 2  
98 2  
200  
200  
200  
200  
200  
200  
200  
200  
200  
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
Under  
examination  
92  
(
(
)
)
Under  
examination  
102  
114  
115  
130  
133  
140  
145  
168  
150  
150  
150  
180  
180  
180  
180  
110 3  
ć
ć
+3  
110  
–2  
Under  
examination  
126 2  
128 2  
136 3  
(
(
(
)
)
)
Under  
examination  
Under  
examination  
125  
250  
50  
125  
250  
50  
141 2  
ć
130  
135  
100  
Under  
examination  
+4  
–2  
163  
200  
(
)
Note: For long lead types add the letter "L" at the end of the part number.  
(Approved Safety Standards File No. UL:E60271, CSA:LR60271, VDE: 4811.6-1171-001, BEAB:C1068, CCC:2002010205004249)  
F series  
Maximum Temp.  
Limit (°C)  
Electrical  
Rating  
Approved Safety  
Standards  
Rated  
Maximum  
Operating  
Temp.  
5  
Type No. of  
Approved  
Standards  
Functioning  
Temp.  
Holding  
Temp.  
(°C)  
Functioning  
2  
4  
Part No.  
RoHS  
1  
3  
Temp.  
UL,VDE,  
BEAB  
CCC  
(°C)  
AC/ Amp. Volt.  
DC (A)  
PS  
E
(°C)  
102  
115  
130  
133  
139  
168  
(°C)  
CSA  
150  
150  
180  
180  
180  
UL  
CSA VDE BEAB CCC  
(V)  
70  
75  
55  
76  
80  
70  
90  
94  
74  
92  
96  
76  
99  
103  
80  
120  
120  
95  
74  
76  
60  
90  
90  
AC  
AC  
2
1
125  
250  
50  
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
Under  
examination  
EYP1BF102  
EYP1BF115  
EYP1BF130  
EYP1BF133  
EYP1BF139  
EYP1BF168  
F102  
F115  
F130  
F133  
F139  
F168  
98 2  
200  
200  
200  
200  
200  
ć
ć
ć
ć
ć
ć
(
)
DC 3.5  
AC  
AC  
DC  
AC  
AC  
2
1
4
2
1
125  
250  
50  
125  
250  
50  
+3  
–2  
110  
ć
80  
105  
105  
90  
108  
108  
92  
115  
115  
95  
135  
142  
110  
Under  
examination  
126 2  
128 2  
(
(
(
(
)
)
)
)
DC 4.5  
AC  
AC  
2
1
125  
250  
50  
Under  
examination  
DC 4.5  
AC  
AC  
DC  
AC  
AC  
DC  
2
1
5
2
1
5
125  
250  
50  
125  
250  
50  
Under  
examination  
135 3  
Under  
examination  
+4  
163  
200  
–2  
Note: For long lead types add the letter "L" at the end of the part number.  
(Approved Safety Standards File No. UL:E60271, CSA:LR60271, VDE: 4811.6-1171-003, BEAB:C1065, CCC:2002010205004248)  
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
Mar. 2005  
Thermal Cutoffs (TCO)  
E series  
Maximum Temp.  
Limit (°C)  
Electrical  
Rating  
Approved Safety  
Rated  
Maximum  
Operating  
Temp.  
5  
Standards  
Type No. of  
Approved  
Standards  
Functioning  
Temp.  
Holding  
Temp.  
(°C)  
Functioning  
2  
4  
Part No.  
RoHS  
1  
3  
Temp.  
UL,VDE,  
BEAB  
CCC  
(°C)  
AC/ Amp. Volt.  
DC (A)  
PS  
E
(°C)  
102  
115  
(°C)  
CSA  
150  
150  
UL  
CSA VDE BEAB CCC  
(V)  
70  
75  
65  
76  
80  
70  
90  
94  
83  
70  
92  
96  
85  
99  
103  
92  
80  
105  
110  
80  
78  
80  
70  
93  
95  
AC 1.5 125  
AC 0.5 250  
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
Under  
examination  
EYP05BE102  
EYP05BE115  
E102  
E115  
98 2  
200  
200  
ć
ć
ć
(
)
DC  
3
50  
AC 1.5 125  
AC 0.5 250  
110 2  
ć
84  
DC  
3
50  
112  
112  
102  
81  
115  
115  
105  
120  
120  
110  
90  
AC 1.5 125  
AC 0.5 250  
Under  
examination  
EYP05BE130  
EYP05BE133  
EYP05BE139  
EYP05BE145  
E130  
E133  
E139  
E145  
130  
133  
139  
145  
126 2  
128 2  
135 2  
141 2  
200  
200  
200  
200  
180  
180  
180  
(
(
(
)
)
)
DC  
DC  
3
5
50  
50  
AC 1.5 125  
AC 0.5 250  
Under  
examination  
ć
ć
DC  
3
50  
AC 1.5 125  
AC 0.5 250  
Under  
examination  
DC  
DC  
3
5
50  
50  
125  
125  
95  
AC 1.5 125  
AC 0.5 250  
ć
ć
DC  
5
50  
Note: For long lead types add the letter "L" at the end of the part number.  
(Approved Safety Standards File No. UL:E60271, CSA:LR60271, VDE: 4811.6-1171-002, BEAB:C1066, CCC:2002010205004246)  
H series  
Maximum Temp.  
Limit (°C)  
Electrical  
Rating  
Approved Safety  
Standards  
Rated  
Maximum  
Operating  
Temp.3  
(°C)  
5  
Type No. of  
Approved  
Standards  
Functioning  
Temp.  
Holding  
Temp.4  
(°C)  
Functioning  
2  
Part No.  
RoHS  
1  
Temp.  
UL,VDE,  
BEAB  
CCC  
(°C)  
AC/ Amp. Volt.  
DC (A)  
PS  
E
(°C)  
102  
115  
130  
133  
139  
168  
CSA  
200  
200  
200  
200  
200  
200  
UL  
CSA VDE BEAB CCC  
(V)  
70  
75  
65  
76  
80  
74  
90  
94  
86  
92  
96  
88  
99  
103  
95  
120  
120  
120  
74  
76  
70  
86  
90  
AC  
AC  
3
2
125  
250  
50  
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
ć
Under  
examination  
EYP2BH102  
EYP2BH115  
EYP2BH130  
EYP2BH133  
EYP2BH139  
EYP2BH168  
H102  
H115  
H130  
H133  
H139  
H168  
98 2  
110 2  
126 2  
128 2  
200  
200  
200  
200  
200  
200  
ć
ć
ć
ć
ć
ć
(
)
DC 3.5  
AC  
AC  
3
2
125  
250  
50  
ć
84  
DC 3.5  
105  
105  
100  
108  
108  
102  
115  
115  
107  
135  
142  
135  
AC  
AC  
3
2
125  
250  
50  
Under  
examination  
(
(
(
(
)
)
)
)
DC 3.5  
AC  
AC  
3
2
125  
250  
50  
Under  
examination  
DC 3.5  
AC  
AC  
3
2
125  
250  
50  
Under  
examination  
135 2  
DC 3.5  
AC  
AC  
3
2
125  
250  
50  
Under  
examination  
+3  
163  
–2  
DC 3.5  
(Approved Safety Standards File No. UL:E60271, CSA:LR60271, VDE: 4811.6-1171-004, BEAB:C1067, CCC:2002010205004245)  
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
Mar. 2005  
Thermal Cutoffs (TCO)  
ML series  
Electrical  
Rating  
Approved Safety  
Standards  
RoHS  
Rated  
Maximum  
Operating  
Temp.  
Maximum  
Temp.  
Type No. of  
Approved  
Standards  
Functioning  
Temp.  
Holding  
Temp.  
(°C)  
Functioning  
2  
4  
Part No.  
1  
3  
Temp.  
Limit  
(°C)  
AC/  
DC  
Amp.  
(A)  
Volt.  
(V)  
5  
(°C)  
(°C)  
(°C)  
UL  
VDE  
CCC  
EYP2ML092  
EYP2ML092U  
EYP2ML098  
EYP2ML098U  
EYP2ML102  
EYP2ML102U  
ML092  
92  
92  
89  
2
55  
55  
60  
60  
65  
65  
60  
60  
65  
65  
70  
70  
135  
135  
135  
135  
135  
135  
DC  
DC  
DC  
DC  
DC  
DC  
2
2
2
2
2
2
50  
50  
50  
50  
50  
50  
ć
ć
ć
ć
ć
ć
Under  
Under  
Under  
+3  
–4  
89  
Application Application Application  
ML098  
98  
94  
2
ć
ć
ć
Under  
Under  
Under  
+3  
98  
94  
–2.5  
Application Application Application  
ML102  
102  
102  
98  
2
ć
ć
ć
Under  
Under  
Under  
+3  
98  
–2.5  
Application Application Application  
(Approved Safety Standards File No. UL:E60271, VDE: 4811.6-1171-004, CCC:2003010205034615), Last letter "U" of part number means  
Pb-free product.  
MU series  
Electrical  
Rating  
Approved Safety  
Standards  
Rated  
Functioning  
Temp.1  
(°C)  
Maximum  
Operating  
Temp.3  
(°C)  
Maximum  
Temp.  
Type No. of  
Approved  
Standards  
Functioning  
Temp.  
Holding  
Temp.4  
(°C)  
2  
Part No.  
RoHS  
Limit  
(°C)  
AC/  
DC  
Amp.  
(A)  
Volt.  
(V)  
5  
(°C)  
UL  
VDE  
CCC  
Under  
examination  
EYP4MU092X  
MU092X  
92  
89  
2
55  
55  
150  
DC  
4
50  
ć
ć
ć
(
)
(Approved Safety Standards File No. UL:E60271, VDE: 4811.6-1171-009, CCC:2003010205034614)  
1 Rated Functioning Temperature (UL: TF, CSA,VDE, BEAB, CCC: Tf)  
The temperature at which a TCO changes its state of conductivity to open circuit with loading detection current only.  
PS  
Tolerance;  
;
7 °C  
E
0
–10  
UL,CSA,VDE, BEAB, CCC;  
°C  
2 Functioning Temperature (Fusing-off temperature)  
The functioning temperature at which a TCO changes its state of conductivity to open circuit in the ambient air oven which increases  
temperature by 1 °C per minute and with loading the detective current 0.1 A or less.  
3 Maximum Operating Temperature.  
The maximum temperature at which a TCO can be maintained while conducting rated current for 3000 h (N, F, E, H series) or 1000 h (ML, MU  
series) For details please refer to specification.  
4 Holding Temperature (UL: TH, CSA: Th, VDE, BEAB, CCC: Tc)  
The maximum temperature at which a TCO can be maintained while conducting rated current for 168 h which will not cause a change in  
state of conductivity to open circuit.  
5 Maximum Temperature Limit (UL: TM, CSA,VDE, BEAB, CCC: Tm)  
The maximum temperature at which a TCO can maintains its mechanical and electrical properties without closing again for 10  
minutes after a TCO has changed its state of conductivity.  
Dimensions in mm (not to scale)  
Axial lead type  
Radial lead type  
B
L
fd  
f
D1  
l
L
l
Dimensions (mm)  
Dimensions (mm)  
C
f
f
f
f
d
L
D
D1  
k
d
A
B
L
N Series  
F Series  
E Series  
9.0 1.0 2.5 0.2  
3 max. 38 3 (78 3) 0.60 0.05  
2.2 max. 38 3 (68 3) 0.53 0.02  
H Series  
5.0 0.5  
4.0 0.5  
2.2 0.3  
55 3  
0.53 0.02  
+0.20  
6.0 1.0 1.85  
–0.15  
5.0 0.5 1.5 0.1 1.8 max. 38 3 (68 3) 0.53 0.02  
() Long lead type  
Thin type  
C
F
A
D
E
B
G
(H)  
Dimensions (mm)  
A
B
C
D
E
F
G
(H)  
(10.25)  
(7.7)  
ML Series  
MU Series  
25.0 0.5  
26.5 0.5  
3.2 0.3  
4.5 0.4  
0.65 0.15  
1.00 0.15  
4.5 0.5  
3.0 0.2  
3.0 0.2  
0.10 0.02  
0.15 0.02  
10.25 0.50  
7.7 0.5  
+0.6  
11.0  
–0.4  
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
Mar. 2005  
Thermal Cutoffs (TCO)  
Marking  
The following items are indicated on TCO.  
• N, F, E, H Series : Type No., Date Code, M Mark( ), <PS>E Mark, Rated Functioning Temperature, Rated Current  
• ML, MU Series : Type No., Date Code, M Mark(  
)
Packaging Methods  
Part No.  
Standard Quantity  
Style  
Bulk  
Mass (Weight) [mg/pc.]  
EYP2BN  
2000 pcs./Box  
2000 pcs./Box  
3000 pcs./Box  
4000 pcs./Box  
4000 pcs./Box  
5000 pcs./Box  
1500 pcs./Box  
2000 pcs./Box  
1000 pcs./Box  
340  
510  
220  
330  
210  
320  
350  
68  
२२२  
२२२  
२२२  
EYP2BN  
EYP1BF  
EYP1BF  
L
L
२२२  
२२२  
२२२  
२२२  
EYP05BE  
EYP05BE  
L
EYP2BH  
EYP2ML  
EYP4MU  
२२२२  
२२२२  
150  
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
Mar. 2005  
Thermal Cutoffs (TCO)  
Safety Precautions (Handling Precautions)  
The following are precautions for individual products. Please also refer to the precautions common to CR Combinations,  
Fuses, and Sensors shown on page EX3 of this catalog.  
Design Applications  
1. Use the TCO within their specified temperature and electrical ratings.  
1) Use the TCO under the maximum operating temperature specified in the individual specification.  
Using the TCO under a higher temperature than the maximum operating temperature may cause premature  
opening or opening delay.  
• When the TCO is continuously used at the temperature close to the functioning temperature, the TCO may  
operate while being used.  
• When the TCO is continuously used at the temperature higher than the maximum operation temperature, the  
TCO may be degraded and may not operate normally at the specified temperature.  
2) The holding temperature is defined as the highest temperature at which the TCO is activated continuously at  
the rated current for 168 hours. The TCO can not be used over 168 hours exceeding the holding temperature.  
3) Equipment should be designed so that its over shoot does not exceed the maximum temperature limit after  
the TCO operates.  
4) If the TCO is activated by voltage higher than the rated voltage or current higher than the rated current, the  
TCO produces excessive heat, resulting in premature opening. The arc generated at this condition of operation  
will result in an abnormality of appearance (crack on body) and insufficient insulation.  
• When TCO is operated in an abnormal mode while the rated voltage and/or the rated current being  
exceeded, it may not cut off the circuit .  
5) Where transient overload is expected to be applied, repeat the tests under the worst conditions.  
6) The TCO cannot be used as a current sensitive fuse.  
2. To fully use the function of the TCO, a suitable TCO for each equipment application must be selected.  
1) Tests should be repeated for the finished equipment to confirm that the TCO does operate as expected.  
2) To improve thermal response of the TCO, put the main body of the TCO and the lead wires(terminals) as  
close to the heat source as possible and the place where the TCO is evenly heated.  
If the temperatures transferred to the main body and to the lead wires(terminals) are largely different from  
each other, improper operation can be expected, causing arcing and deterioration of insulation.  
3. Avoid application of excessive vibration and mechanical stress to the TCO. Otherwise, failure of the fusible  
alloy or lead wires, or damage to the main body may result.  
4. When sealing the TCO with resin, select a resin that does not corrode the seals or the lead wires(terminals).  
When sealing the overall TCO with resin, determine the fixing conditions by repeating the test using your final  
product to check whether or not the resin properties (e.g. expansion, contraction, and curing temperature)  
affect the TCO and whether or not the TCO can operate normally.  
5. When immersing equipment with a TCO in varnish or solvent and then drying it, repeat the test to check whether  
or not the varnish or solvent used dissolved the coating of the TCO or caused damage, such as cracks, before  
performing the treatment again.  
6. Do not use under the following environments.  
1) In liquids such as water, oil, chemical and organic solvents  
2) In direct sunlight, outdoors or in dusty atmospheres  
3) In places where water condensation occurs  
Use in the following environments may affect the performance of the TCO; Verify performance and reliability  
before production use.  
(1) In places full of corrosive gases such as sea breeze, Cl2, H2S, NH3, SO2 and NO2  
(2) In environments with high static electricity and/or strong electromagnetic waves.  
7. Do not use the TCO in aerospace equipment, atomic energy equipment, military weapons, life saving  
equipment, etc.  
Instruction  
1. Forming and Cutting  
1) Lead wires(terminals) are to be bent or cut at least 3 mm away from the TCO seals to avoid damaging the  
TCO . (axial / radial type) or body (thin type). The TCO seals (axial / radial type) shall not be grasped with  
any tools or holders. Terminals of thin type TCO are to be grasped before they are bent . (See Fig.1)  
2) The lead wires and terminals shall not be nicked, fractured or burned.  
The body and/or seals must not be damaged, burned or overheated.  
3) It is recommended that experimental assembly trials, should be done so that it can be verified that  
manufacturing procedures will not exceed the maximum tested "pull" and "push" forces of 20 N (ML series:5 N,  
MU series:10 N) and 5 N respectively on the lead wires (terminals), or induce excessive twisting or the like.  
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
Mar. 2005  
Thermal Cutoffs (TCO)  
Bending  
Cutting  
grasped  
grasped  
> 3 mm  
> 3 mm  
> 3 mm  
> 3 mm  
> 3 mm  
> 3 mm  
Fig-1  
2. Soldering, Welding, Calking  
1) Lead wires are to be soldered with the standard conditions shown in Table 1.  
Excessive soldering heat and soldering time may cause damage to a TCO.  
If higher temperature, longer time or shorter lead length exist rather than the conditions of Table 1 ,it is  
recommended to run tests for finding the soldering conditions that do not damage the TCO. Also, use of  
tools such as pliers are recommended to dissipate the soldering heat by grasping lead wires between the  
TCO body and soldering point.  
2) Avoid preheating and gradual cooling as much as possible. However if preheating and gradual cooling is  
done, set the process conditions after confirming that the TCO is not affected by these procedures.  
3) Do not use reflow soldering.  
4) Thin type (ML, MU series) is not to be soldered.  
5) If water or solvent is used for cleaning flux after soldering, check and confirm the reliability of the agent.  
6) Lead wires are to be clamped at least 3 mm away from the seals.  
Improper connections may cause damage to the seals or other parts and may result in nuisance tripping of  
the devices due to the generation of excessive heat at a faulty high resistance junction.  
7) Set the conditions for welding and calking only after checking contact resistance and connection strength.  
8) When resoldering or rewelding, cool the TCO under room conditions.  
9) When the TCO is heated by soldering or welding, be careful not to pull, push or twist the TCO lead wires.  
Table-1 Soldering Conditions  
Temperature of Soldering: 300 °C Time: 3 s  
Soldering point  
Lead Length ( )  
Type No.  
k
25 mm  
20 mm  
N082, N088  
F102  
E102, E115  
H102, H115  
l
N098, N109  
N110  
F115, F130  
F133, F139  
E130, E133  
E139, E145  
H130, H133  
H139  
N124, N126  
N135, N143  
15 mm  
10 mm  
F168  
H168  
l
N163  
3. The use of sufficiently flexible, appropriate free length and proper size wire should be used for splice connection.  
Connection including connectors used for splicing shall be of the low resistance type, and they shall be made  
mechanically secure.  
4. Where the lead wires of the TCO is tied with string, put them at least 10 mm apart from the seals of the main  
body of the TCO.  
5. Quality control notes.  
1) Measurement of resistance between lead wires (terminals) and checking of the internal status with X-rays are  
effective means to confirm the status of the TCO on delivery and after mounting in the equipment.  
6. Storage method  
1) Store the TCO in packing cases or in polyethylene bags within the temperature range -10 °C to +40 °C and  
RH of 30 % to 75 %. Store them at a location where no rapid changes of temperature or humidity or no  
direct sunlight is applied. The location must also be free from vibration and shock .  
2) Avoid storage in places containing corrosive gases such as sea breeze, Cl2, H2S, NH3, SO2 and NO2.  
3) The period of guarantee for performance such as solderability is for one year after our delivery; and this  
condition applies only in the case where the storage method specified in above has been followed.  
7. Do not repair a TCO. Replace it with a new part.  
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
Mar. 2005  
Safety Precautions (Common precautions for CR Combinations, Fuses, and Sensors)  
• When using our products, no matter what sort of equipment they might be used for, be sure to make a written  
agreement on the specifications with us in advance. The design and specifications in this catalog are subject  
to change without prior notice.  
• Do not use the products beyond the specifications described in this catalog.  
• This catalog explains the quality and performance of the products as individual components. Before use, check  
and evaluate their operations when installed in your products.  
• Install the following systems for a failsafe design to ensure safety if these products are to be used in equipment  
where a defect in these products may cause the loss of human life or other significant damage, such as damage to  
vehicles (automobile, train, vessel), traffic lights, medical equipment, aerospace equipment, electric heating  
appliances, combustion/gas equipment, rotating equipment, and disaster/crime prevention equipment.  
Systems equipped with a protection circuit and a protection device  
Systems equipped with a redundant circuit or other system to prevent an unsafe status in the event of a single fault  
(1) Precautions for use  
• These products are designed and manufactured for general and standard use in general electronic equipment  
(e.g. AV equipment, home electric appliances, office equipment, information and communication equipment)  
• These products are not intended for use in the following special conditions. Before using the products,  
carefully check the effects on their quality and performance, and determine whether or not they can be used.  
1. In liquid, such as water, oil, chemicals, or organic solvent  
2. In direct sunlight, outdoors, or in dust  
2
2
3
2
2
3. In salty air or air with a high concentration of corrosive gas, such as Cl , H S, NH , SO , or NO  
4. In an environment where strong static electricity or electromagnetic waves exist  
5. In an environment where these products cause dew condensation  
6. Sealing or coating of these products or a printed circuit board on which these products are mounted, with  
resin or other materials  
• These products generate Joule heat when energized. Carefully position these products so that their heat will  
not affect the other components.  
• Carefully position these products so that their temperatures will not exceed the category temperature range due  
to the effects of neighboring heat-generating components. Do not mount or place heat-generating components  
or inflammables, such as vinyl-coated wires, near these products (except Thermal Cutoffs).  
• Note that non-cleaning solder, halogen-based highly active flux, or water-soluble flux may deteriorate the  
performance or reliability of the products.  
• Carefully select a flux cleaning agent for use after soldering. An unsuitable agent may deteriorate the performance  
or reliability. In particular, when using water or a water-soluble cleaning agent, be careful not to leave water  
residues. Otherwise, the insulation performance may be deteriorated.  
(2) Precautions for storage  
The performance of these products, including the solderability, is guaranteed for a year from the date of arrival  
at your company, provided that they remain packed as they were when delivered and stored at a temperature  
of 5 °C to 35 °C and a relative humidity of 45 % to 85 %.  
The performance of Combinations(EMI Filters) is guaranteed for 6 months or a year from the outgoing inspection  
date indicated on the packages, provided that they are stored at a temperature of -5 °C to +40 °C and a relative  
humidity of 40 % to 60 %. Check the guarantee period in the specifications. The performance of Thermal  
Cutoffs is guaranteed for a year from the outgoing inspection date indicated on the packages, provided that  
they are stored at a temperature of -10 °C to +40 °C and a relative humidity of 30 % to 75 %.  
Even within the above guarantee periods, do not store these products in the following conditions. Otherwise,  
their electrical performance and/or solderability may be deteriorated, and the packaging materials (e.g. taping  
materials) may be deformed or deteriorated, resulting in mounting failures.  
2
2
3
2
2
1. In salty air or in air with a high concentration of corrosive gas, such as Cl , H S, NH , SO , or NO  
2. In direct sunlight  
<Package markings>  
Package markings include the product number, quantity, and country of origin.  
In principle, the country of origin should be indicated in English.  
Mar. 2005  
– EX3 –  
厂商 型号 描述 页数 下载

PANASONIC

EYP-2BN126 温度保险丝( TCO )[ Thermal Cutoffs (TCO) ] 8 页

PANASONIC

EYP-2MT098B 温度保险丝( TCO ) /热熔断体[ Thermal Cutoffs (TCO)/ Thermal-Links ] 6 页

VISHAY

EYP01CF333R02 [ CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 385 V, 330 uF, CHASSIS MOUNT, ROHS COMPLIANT ] 7 页

VISHAY

EYP01CM415M02 [ CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 160 V, 1500 uF, CHASSIS MOUNT, ROHS COMPLIANT ] 7 页

VISHAY

EYP01H0433002 [ CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 350 V, 3300 uF, CHASSIS MOUNT, ROHS COMPLIANT ] 7 页

VISHAY

EYP01H0568H01 [ CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 50 V, 68000 uF, CHASSIS MOUNT, ROHS COMPLIANT ] 7 页

VISHAY

EYP01HM422X02 [ CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 400 V, 2200 uF, CHASSIS MOUNT, ROHS COMPLIANT ] 7 页

VISHAY

EYP01HM433N02 [ CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 250 V, 3300 uF, CHASSIS MOUNT, ROHS COMPLIANT ] 7 页

VISHAY

EYP01HM610E01 [ CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 25 V, 100000 uF, CHASSIS MOUNT, ROHS COMPLIANT ] 7 页

VISHAY

EYP01K0633C01 [ CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 10 V, 330000 uF, CHASSIS MOUNT, ROHS COMPLIANT ] 7 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.181016s