5 Watt WF Single Output Series DC/DC Converters
General Specifications*
Output Parameters*
All Models
Units
Model
12S5.1000WF
Units
Output Trim Function
Output Voltage
5
VDC
MIN
MAX
MIN
TYP
MAX
0
1000
4.950
5.000
5.050
Input Resistance
Trim Range
Isolation
TYP
MIN
100
±10
kohms
%
Rated Crrent (4)
mA
Voltage Range
100% Load
VDC
Isolation (10)
None
Load Regulation
0-100% Full Load
Line Regulation
Vin = Min-Max VDC
Short Term Stability (5)
Long Term Stability
TYP
MAX
TYP
MAX
TYP
TYP
TYP
0.05
0.20
0.05
0.20
0.05
0.20
500
%
%
Environmental
Case Operating Range
No Derating
MIN
MAX
MIN
MAX
MIN
MAX
TYP
-25
80
-40
90
-55
105
10
°C
°C
%
%/kHrs
µs
mV
peak
Case Functional Range (11)
Storage Range
Transient Response (6)
°C
Dynamic Response (7)
Input Ripple Rejection (8)
Noise, 0-20MHz bw
TYP
TYP
200
23
Thermal Impedance (12)
General
°C/Watt
dB
Unit Weight
TYP
1.5
oz
TYP
MAX
TYP
MAX
20
40
50
150
6.8
mV P-P
Mounting Kits
MS6 & MS15
Temperature Coefficient
Overvoltage Clamp (9)
ppm/°C
VDC
TYP
Short Circuit Protection
to Common
Continuous, 8 Hours Minimum
Current Limit
NOTES:
3
3
4
5
All parameters measured at Tc=25°C, nominal input voltage
and full rated load unless otherwise noted. Refer to the
CALEX Application Notes for the definition of terms,
measurementcircuitsandotherinformation.
TRIM
DOWN
*
10K
TRIMPOT
4
(2) PeaktoPeakinputreflectedrippleisequaltotheDCoutputcurrent
when measured into a zero impedance source resistance. For
reduced input ripple use the suggested input filter circuit.
TRIM
UP
(3) For long term short circuit protection of the converters, install a
slowblowfuseintheinputcircuit.Chooseafusesizethatis125%
of your applications actual input current and does not exceed
115% of the full load input current.
5
Figure 1. CONNECTIONS FOR OUTPUT TRIM
(4) No minimum load required.
A
(5) Shorttermstabilityisspecifiedaftera30minutewarmupatfullload,
constant line and recording the drift over a 24 hour period.
(6) Aftera25%stepchangeoftheload,theoutputvoltagewillbewithin
±1% of the final value within the transient response time.
12S5.1000WF
L1
(7) Dynamic response is the peak overshoot during a transient as
defined in note 4 above.
2
1
+OUT 3
+IN
+
7 - 32
VDC
(8) The input ripple rejection is specified for DC to 120 Hz ripple with
a modulation amplitude of 1% of Vin.
C1 C2
4
5
LOAD
TRIM
CMN
(9) For module protection only, see also note 3.
-IN
(10) Case is tied to pin 1. Input and output commons are connected
internally.
(11) Thefunctionaltemperaturerangeisintendedtogive additionaldata
forevaluatingthispowersupply.Atthelowfunctionaltemperature
the power supply will function with no side effects, however,
sustainedoperationatthehighfunctionaltemperaturewillreduce
expected operational life. The data sheet specifications are not
guaranteedoverthefunctionaltemperaturerange.
Figure 2. INPUT FILTER CIRCUIT
197
ThiscircuitwillreducetheinputreflectedrippleoftheWFSeriesto30
mA P-P(0-20 MHz bw). L1 is 10 turns wound on a MICROMETALS
T30-26coreorany6-10µH,1ampinductor.C1andC2arePanasonic
47µF, 35V, HF capacitors (ECE-A1VF470R) or equivalent.
(12) The case thermal impedance is the case temperature rise over
ambient per watt dissipated.
NOTE: For lowest noise operation use single point grounding to pin 5
for both input and output circuits.
axFACTS:
2401 Stanwell Drive
Concord, CA 94520-4841
(510) 687-4411 • Fax (510) 687-3333
http://www.calex.com
5