DC-DC Converter
JWL50 Series
Input
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
24 V nominal
9
18
36
75
VDC
VDC
Input Voltage Range
Input Filter
48 V nominal
Internal Pi type
50
24 V models
48 V models
Input Surge
VDC for 1 s
100
ON: Logic high (3.5-12 V) or open circuit
OFF: Logic low (<1.2 V) or short pin 2 to pin 6
Remote On/Off
Output
Characteristic
Output Voltage
Initial Set Accuracy
Output Trim
Minimum
Typical
Maximum
Units
VDC
%
Notes & Conditions
3.3
30
1.0
10
See Models and Ratings table
At full load
%
See Application Notes
Minimum Load
Line Regulation
Load Regulation
A
No minimum load required
From minimum to maximum input at full load
From 0 to full load
0.5
0.5
%
%
Recovery within 1% in less than 250 µs for a 25% load
change.
Transient Response
Ripple & Noise
3
5
% deviation
3.3 & 5V output / other models. 20 MHz bandwidth.
Measured using 1µF MLCC & 10µF tantalum capacitor.
100/150
mV pk-pk
%
Overload Protection
150
Short Circuit Protection
Maximum Capacitive Load
Temperature Coefficient
Continuous Trip & Restart (Hiccup mode), with auto recovery
See Models and Ratings table
0.02
%/˚C
General
Characteristic
Minimum
Typical
Maximum
Units
%
Notes & Conditions
See Models and Ratings table
60 s
Efficiency
90
Isolation: Input to Output
Isolation Resistance
Isolation Capacitance
Switching Frequency
Power Density
1500
VDC
Ω
9
10
At 500 VDC
2200
58
pF
285
kHz
3
W/in
Mean Time Between Failure
Weight
230
kHrs
lb (g)
MIL-HDBK-217F, +25 °C GB
0.074 (34.0)
Environmental
Characteristic
Minimum
-40
Typical
Maximum
+105
Units
°C
Notes & Conditions
Operating Temperature
Storage Temperature
Case Temperature
Humidity
See Derating Curve.
-50
+125
°C
+105
95
°C
%RH
Non-condensing
Cooling
Natural convection
Thermal impedance to air
12.1/9.8
°C/W
No heatsink / with heatsink
EMC: Emissions
Phenomenon
Standard
EN55022
Test Level
Notes & Conditions
Conducted
Class A
See Application Notes
www.xppower.com