SIGNAL ACQUISITION SYSTEM
Bandwidth –
CURSORS
TDS 200
Series
Characteristics
Types – Voltage, Time.
TDS 210: 60MHz.
TDS 220: 100MHz.
TDS 224: 100MHz.
Measurements – DT, 1/DT, DV.
WAVEFORM PROCESSING
Arithmetic Operators – Add, Subtract.
Sample Rate –
1 GS/s on each channel.
Sources – CH1±CH2, CH3±CH4.
Autoset – Single button automatic setup on
selected input signal for vertical, horizontal,
and trigger systems.
Channels –
TDS 210 and TDS 220: 2 identical channels
plus external trigger.
TDS 224: 4 identical channels.
DISPLAY SYSTEM
Sensitivity (with calibrated fine
adjustment) –
Robust, backlit LCD with adjustable multi-
level contrast.
2 mV to 5V/div (bandwidth limited to
20 MHz at 2 mV/div and 5 mV/div, in all
modes, and 20 MHz at 10 mV/div in Peak
Detect mode).
Interpolation – Sin(x)/x.
Modes – Vector, Dots, Dot Persistence.
Format – YT and XY.
Vertical Zoom –
Vertically expand or compress a live or
stopped waveform.
HARDCOPY CAPABILITY
Printer/File Formats – Thinkjet, Deskjet,
Laserjet, Epson (9 or 24 pin), BMP, PCX,
IMG, EPS, DPU 411, DPU 412.
CALIBRATED POSITION RANGE
Hardcopy Layout – Landscape or Portrait.
Volts/Div Setting
Offset Range
TDS2CM COMMUNICATIONS EXTENSION MODULE
Centronics-type Parallel Port
2 mV to 200 mV/div
>200 mV to 5 V/div
±2 V
±50 V
RS-232 Programmability – Full talk/listen
modes. Control of all modes, settings, and
measurements. Baud Rate up to 19,200.
9-Pin, DTE.
DC Gain Accuracy – ± 3%. (± 4% at 2
mV/div and 5 mV/div)
Vertical Resolution –
8 bits (256 levels over 10.24 vertical divi-
sions).
GPIB Programmability – Full talk/listen
modes. Control of all modes, settings, and
measurements (IEEE Std 488-1987).
AUTOMATIC MEASUREMENTS
Period, Frequency, Cycle RMS, Mean, Peak
to Peak.
TDS2MM MEASUREMENT EXTENSION MODULE
FFT– Windows: Hanning, Flat Top,
Rectangular.
ACQUISITION MODES
Sample points: 2048.
Sample, Average, Peak Detect – High fre-
quency and random glitch capture; captures
glitches as narrow as 10 ns using acquisi-
tion hardware at all time/div settings
between 5 µs/div and 5 s/div.
Automatic Measurements – Rise/Fall Time,
Positive/Negative Pulse Width.
Interface – Centronics, RS-232, GPIB.
ENVIRONMENTAL AND SAFETY
TIME BASE SYSTEM (MAIN AND WINDOW)
Horizontal Zoom – Horizontally expand or
Temperature –
0° C to +50° C (operating).
-20° C to +60° C (non-operating).
compress a live or stopped waveform.
Time/Division Range – 5 ns to 5 s/div.
Humidity –
Record Length – 2500 sample points per
channel.
Up to 90% RH at or below +40° C;
Up to 60% RH from 41° C to 50° C (operat-
ing and non-operating).
Horizontal Accuracy – ± 0.01%.
Altitude –
Up to 2000 m (operating).
NON-VOLATILE STORAGE
Waveform Display – Two 2500 point refer-
ence waveforms.
Electromagnetic Emissions –
Meets Directive 89/336/EEC for Electromag-
netic Compatibility;
FCC Code of Federal Regulations, 47 CFR,
Part 15, Subpart B, Class A.
Waveform Storage – Two 2500 point refer-
ence waveforms (TDS 210, TDS 220), four
2500 point reference waveforms
(TDS 224).
Safety – UL 3111, EN61010, CAN/CSA-
C22.2 No. 1010.1-92.
Setups – 5 front panel setups.
TRIGGERING SYSTEM (MAIN ONLY)
PHYSICAL CHARACTERISTICS
Trigger Type – Edge (Rising or Falling),
Video, Set to 50%.
Dimensions
mm
in.
Width
Height
Depth
304.8
151.4
120.7
12.0
5.96
4.75
Video Trigger Type – Triggers on Fields or
Lines from sync-negative composite video;
triggers on broadcast standard NTSC, PAL,
or SECAM video.
Weight
kg
lb.
Trigger Modes – Auto, Normal, Single
Sweep.
oscilloscope only
w/accessories
1.5
1.7
3.25
3.75
Trigger Source –
TDS 210 and TDS 220: CH1, CH2, Ext,
Ext/5.
TDS 224: CH1, CH2, CH3, CH4
Trigger View – Displays trigger signal while
trigger view button depressed.