For more information, please visit the product page.
CUI Inc │ SERIES: PYBJ6 │ DESCRIPTION: DC-DC CONVERTER
date 06/24/2019 │ page 3 of 10
PROTECTIONS
parameter
conditions/description
output shut down
min
110
110
typ
max
160
200
units
%
over voltage protection
over current protection
short circuit protection
hiccup, auto recovery
140
%
hiccup, continuous, auto recovery
SAFETY AND COMPLIANCE
parameter
conditions/description
min
typ
max
units
input to output for 1 minute at 5 mA
input to case8 for 1 minute at 5 mA
output to case8 for 1 minute at 5 mA
input to output for 1 minute at 1 mA
input to case8 for 1 minute at 1 mA
output to case8 for 1 minute at 1 mA
500
500
500
1,500
1,500
1,500
Vac
Vac
Vac
Vdc
Vdc
Vdc
isolation voltage
input to output at 500 Vdc
input to case8 at 500 Vdc
output to case8 at 500 Vdc
100
100
100
MΩ
MΩ
MΩ
isolation resistance
isolation capacitance
safety approvals
conducted emissions
radiated emissions
ESD
input to output, 100 kHz / 0.1 V
1,000
pF
UL 62368-1, IEC 62368-1, EN 62368-1
CISPR32/EN55032, class A (no external circuit); class B (external circuit required, see Figure 3)
CISPR32/EN55032, class B (external circuit required, see Figure 4)
IEC/EN61000-4-2, contact ±6 kV, class B
radiated immunity
EFT/burst
IEC/EN61000-4-3, 10 V/m, class A
IEC/EN61000-4-4, ±2 kV, class B (external circuit required, see Figure 2)
IEC/EN61000-4-5, line-line ±2 kV, class B (external circuit required, see Figure 2)
IEC/EN61000-4-6, 3 Vr.m.s, class A
surge
conducted immunity
MTBF
as per MIL-HDBK-217F, 25°C
1,000,000
hours
RoHS
yes
Note:
8. Only applies to versions with case.
cui.com