XWS DC-DC Series Data Sheet
100 to 192 Watts
Features
• High power package
• Wide input range
• Trim and enable pins
• Remote sense pins
• 500V isolation
Description
XWS dc-dc converters are high-powered converters which cover a wide range of industrial and general applications.
Available input voltages include 12V, 24V, 40V, and 48V; output voltages are available from 5V to 24V. The XWS
features remote sense leads for accurate point of load regulation. For dual and triple output high power solutions, see
the XWD and XWT Series of converters, respectively.
Efficiency vs. Load (24V Input)
95
Technical Specifications
Input
90
Voltage Range
12 VDC Nominal
24 VDC Nominal
40 VDC Nominal (Wide Input)
48 VDC Nominal
Input Ripple Current
Reverse Input Current
10 - 20 VDC
18 - 36 VDC
20 - 60 VDC
36 - 72 VDC
85
80
75
XWS2415
20% I Max.
in
100% I Max.
in
10
20
30
40
50
60
70
80
90 100
LOAD %
Efficiency vs. Load (48V Input)
Output
95
90
85
80
75
70
65
Setpoint Accuracy
±1%
Line Regulation V Min. - V Max., I
Rated
±0.2% V
±1% V
in
in
out
out
Load Regulation I
Min. - I
Max., V Nom.
out
out
in
out
Minimum Output Current
10 % l
rated
out
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
25% I
out
4% Vo
500 μs
±10%
XWS4805
XWS4815
10
20
30
40
50
60
70
80
90 100
LOAD %
General
Turn-On Time
10 ms
Notes
Remote Shutdown
Switching Frequency
Isolation
TTL And CMOS Compatible, Positive Logic
200 kHz
†
MTBF predictions may vary slightly from model to model.
Industrial temp range available
††
Input - Output
500 VDC
Temperature Coefficient
Case Temperature
Operating Range
±0.02%/°C
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
-25 To +85°C††
-40 To +125°C
105 To 115°C
95%
5 g, 10 - 55 Hz
Consult Factory
Consult Factory
15.4 oz
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Storage Range
Thermal Shutdown Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
MTBF† (Bellcore TR-NWT-000332)
Safety
Safety: Fusing Recommended.
+ See following two pages for Terminal Strip Option Drawing
Weight (Approx.)
SEP 25, 2006 revised to MAR 09, 2007
Page 1 of 3
www.power-one.com