PZB300
• Delta EMI suppressor, classes X2 and Y2, metallized paper
• 0.1 and 0.15 µF X2, 2200, 3300 and 4700 pF Y2, 275 VAC, +100 °C
• Class X2 and Y2
• Compact size
• Self-extinguishing encapsulation.
• PCB mounting or fast-on connection
• Excellent self-healing properties.
Ensures long life even when subjected to
frequent overvoltages.
• High dU/dt capability.
• Good resistance to ionisation due to
impregnated dielectric material.
• The impregnated paper ensures
excellent stability giving oustanding
reliability properties, especially in
applications having continuous
operation.
TYP ICAL AP P LICATIONS
CONS TRUCTION
Multi-layer metallized paper. Encapsulated
and impregnated in self-extinguishing
material meeting the requirements of UL
94V-0.
Interference suppressors with X2 + 2 x Y2
capacitors in a delta configuration.
max 24.0
max 12.5
TECHNICAL DATA
∅ 0.8
Rated voltage
275 VAC 50/60 Hz
0.1 and 0.15
21.3
± 1.5
Capacitance X value, µF
Capacitance Y value, pF
Capacitance tolerance
Temperature range
Climatic category IEC
Approvals
0.8
4.75 ± 0.1
2200, 3300 and 4700
± 20%
max 24.0
max 12.5
–40 to +100°C
40/100/56/B
S, UL, CSA
∅ 0.8
20.0 ± 0.5
Dis s ipation factor tanδ
Ins ulation res is tance
≤ 1.3 % at 1 kHz
≥ 12000 MΩ
Measured at 500 VDC after 60 s, +23°C
Tes t voltage between
terminals
The 100% screening factory test is carried
out at 2150 VDC for X2 capacitors and at
3000 VDC for Y2 capacitors. The voltage
level is selected to meet the requirements
in applicable equipment standards. All
electrical characteristics are checked after
the test.
CX
CY CY
1
2
ENVIRONMENTAL TES T DATA
Suppres s ion vs . frequency
Vibration
Bump
IEC 60068-2-6
Test Fc
3 directions at 2 hour each
10 – 500 Hz at
No visible damage
No open or short circuit
dB
70
Attenuation
0.75 mm or 98 m/s2
(PZB300MC.. mounted on PC-board)
60
50
40
30
20
10
0
CX
IEC 60068-2-29
Test Eb
4000 bumps at
390 m/s2
No visible damage
No open or short circuit
CY
Solderability IEC 60068-2-20
Solder globule
method
Wetting time < 1 s
Test Ta
f
Active
flammability
EN 132400
1
3
5
10
30
100 200 MHz
Attenuation, typical values ,
0.1 µF + 2 x 2200 pF
Passive
flammability EN 132400
IEC 60384-14 (1993)
Humidity
IEC 60068-2-3
Test Ca
+40°C and
90 – 95% R.H.
56 days
170