VL (AZ8)
MOUNTING DIMENSIONS
Surface mounting
mm inch
Through hole mounting
Rear mounting
t
M4 .157 tap
mounting nut
(
)
P=0.7
M5 .197 mounting screw
M4 .157
mouting screw
4-4.5 .177 dia.
4-5.5 .217 dia.
M4 .157
mounting screw
56±0.2
2.205±.008
56±0.3
2.205±.012
56±0.3
2.205±.012
21±0.2
.827±.008
washer
21±0.3
.827±.012
21±0.3
.827±.012
washer
washer
Depth of screw holes > 15mm .591inch
Thickness of panel < 5mm .197inch
Length of bolt < panel thickness t+7mm .276inch
HEAD DIRECTION CHANGE
(Roller arm, adjustable roller arm, adjustable rod types)
Actuator heads may be
(
)
Lock screw Black
moved in 90° increments
to any of four directions,
by removing one screw.
•Useꢀwhereꢀthereꢀwillꢀbeꢀdirectꢀcontactꢀwithꢀ
organic solvents, strong acids or alkalis, or
direct exposure to their vapors.
•Useꢀwhereꢀinflammableꢀorꢀcorrosiveꢀgasesꢀ
exist.
CAUTIONS
2. Because these switches are not of
1. When overtravel is too large, life is short-
ened due to possible damage to the mech-
anism. Please use in the following appropri-
ate range.
immersion protected construction, their use
in water or oil should be avoided. Also,
locations where water or oil can normally
impinge upon the switch or where there is
an excessive accumulation of dust should
be avoided.
Types
Plunger
(AZ8111, 8112, 8122)
Roller Arm
(AZ8104, 8107, 8108)
Flexible Rod
(AZ8166, 8169)
Overtravel
1.5 to 2.0mm
.059 to .079inch
4. In order to maintain the reliability at a
high level under practical conditions of use,
the actual operating conditions should be
checked for the benefit of the quality of the
product.
20 to 30°
15 to 20mm .591 to
.787inch (at the top)
3. The use of these switches under the fol-
lowing conditions should be avoided. If the
following conditions should become neces-
sary, we recommend consulting us first.
5. Mounting
7. Matters to be attended to in using spring
type VL Limit Switch with indicator.
1) When loads are connected to both N.O.
and N.C. only the indicatin at non-operation
time can be used.
2) Take special care not to damage or
deform the contact spring during change of
indicator holder direction or during connec-
tion work.
3) In the case of VL Limit Switch with Neon
lamp, if the indicator is connected in series
in a 100V circuit, the indicator ceases to be
lighted.
However, for a 200V circuit, up to 2 lamps
can be connected in series.
Three cover screws should be fasten uni-
formly. The rubber for opening cord should
be corrected as normal condition after con-
necting the wire.
6. How to change the indicator holder.
1) As shown in the photograph, wrench a
minus-driver in the gap between the cover
and the part of the indicator holder indicat-
ed by the arrow in the direction of insertion,
and raise the lamp a little.
8. Matters to be attended to in using lead
wire type VL with lamp.
1) When loads are connected to both N.O.
and N.C. indication can be given on both
N.O. and N.C. sides, but it is impossible to
connect the indication circuit to the load in
series.
2) After removing the indicator holder, insert
it in the reverse direction, and push it in
until a snap is heard.
3) After changing the direction of the indica-
tor holder, put the cover on it in such a way
that the spring touches the top of the termi-
nal screw.
(Unless the spring rests completely on the
terminal screw, distortion of the spring, fail-
ure in lighting of the lamp or short circuit
may result.)