IDT5V40512
LOCO™ PLL CLOCK MULTIPLIER
CLOCK MULTIPLIER
Crystal Load Capacitors
External Components
The device crystal connections should include pads for
small capacitors from X1 to ground and from X2 to ground.
These capacitors are used to adjust the stray capacitance of
the board to match the nominally required crystal load
capacitance. Because load capacitance can only be
increased in this trimming process, it is important to keep
stray capacitance to a minimum by using very short PCB
traces (and no vias) between the crystal and device. Crystal
capacitors, if needed, must be connected from each of the
pins X1 and X2 to ground.
Decoupling Capacitor
As with any high-performance mixed-signal IC, the
IDT5V40512 must be isolated from system power supply
noise to perform optimally.
A decoupling capacitor of 0.01µF must be connected
between VDD and GND. It must be connected close to the
IDT5V40512 to minimize lead inductance. No external
power supply filtering is required for the IDT5V40512.
Series Termination Resistor
The value (in pF) of these crystal caps should equal (C -12
L
pF)*2. In this equation, C = crystal load capacitance in pF.
Example: For a crystal with a 16 pF load capacitance, each
crystal capacitor would be 8 pF [(16-12) x 2 = 8].
A 33Ωterminating resistor can be used next to the CLK pin.
The total on-chip capacitance is approximately 12 pF. A
parallel resonant, fundamental mode crystal should be
used.
L
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the IDT5V40512. These ratings, which
are standard values for IDT commercially rated parts, are stress ratings only. Functional operation of the device at
these or any other conditions above those indicated in the operational sections of the specifications is not implied.
Exposure to absolute maximum rating conditions for extended periods can affect product reliability. Electrical
parameters are guaranteed only over the recommended operating temperature range.
Item
Rating
Supply Voltage, VDD
All Inputs and Outputs
7 V
-0.5 V to VDD+0.5 V
-40 to +85° C
-65 to +150° C
260°C
Ambient Operating Temperature (industrial)
Storage Temperature
Soldering Temperature
Recommended Operation Conditions
Parameter
Min.
Typ.
Max.
+85
Units
° C
Ambient Operating Temperature (industrial)
Power Supply Voltage (measured in respect to GND)
-40
+3.0
+3.3
+3.6
V
IDT™ LOCO™ PLL CLOCK MULTIPLIER
4
IDT5V40512
REV D 51309