Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PYB15-T & PYB15-U │ DESCRIPTION: DC-DC CONVERTER
date 02/15/2021 │ page 3 of 8
SAFETY AND COMPLIANCE (CONTINUED)
parameter
conditions/description
min
typ
max
units
safety approvals
conducted emissions
radiated emissions
ESD
certified to 62368-1: EN
CISPR22/EN55022, class A, class B (external circuit required, see Figure 1-b)
CISPR22/EN55022, class A, class B (external circuit required, see Figure 1-b)
IEC/EN61000-4-2, class B, contact ± 4kV
radiated immunity
EFT/burst
IEC/EN61000-4-3, class A, 10V/m
IEC/EN61000-4-4, class B, ± 2kV (external circuit required, see Figure 1-a)
IEC/EN61000-4-5, class B, ± 2kV (external circuit required, see Figure 1-a)
IEC/EN61000-4-6, class A, 3 Vr.m.s
surge
conducted immunity
voltage dips & interruptions
MTBF
IEC/EN61000-4-29, class B, 0%-70%
as per MIL-HDBK-217F @ 25°C
1,000,000
hours
RoHS
2011/65/EU
ENVIRONMENTAL
parameter
conditions/description
min
-40
-55
5
typ
max
85
units
°C
operating temperature
storage temperature
storage humidity
case temperature
vibration
see derating curves
125
95
°C
non-condensing
%
at full load, Ta=71°C
105
°C
10~55 Hz for 30 min. along X, Y and Z axis
10
G
MECHANICAL
parameter
conditions/description
min
typ
max
units
chassis mount: 76 x 31.5 x 21.2
chassis mount with heatsink: 76 x 31.5 x 25.10
U-Frame: 52.32 x 54.99 x 19.05
mm
mm
mm
mm
dimensions
case material
weight
U-Frame with heatsink: 52.32 x 54.99 x 22.90
aluminum alloy
chassis mount
chassis mount with heatsink
U-Frame
50
58
58
66
g
g
g
g
U-Frame with heatsink
cui.com