USER GUIDE TB-9036  
Constant Monitor  
Installation, Operation and Maintenance  
Constant Monitor WSMONITOR1 uses a solid state  
impedance design to constantly test the connection  
integrity of the entire ground system including the  
person, the wristband and the coiled cord. Constant  
Monitors WSMONITOR2 and WSMONITOR3 also  
provide worksurface monitoring. This system is fully  
automatic and activates when a wrist strap is plugged  
into the unit. A green light indicates connection and a  
red light indicates there is no connection. The unit is  
powered and grounded by the AC adapter.  
Figure 1. SCS WSMONITOR1 Constant Monitor  
The Constant Monitor is available in six models:  
Power  
Adapter  
Input  
Item  
Operator(s) Mat(s)  
WSMONITOR1  
1
1
1
1
2
2
0
0
1
1
1
1
120VAC  
Figure 2. SCS WSMONITOR2 Constant Monitor  
WSMONITOR1-  
230VAC  
230VAC  
120VAC  
230VAC  
120VAC  
230VAC  
WSMONITOR2  
WSMONITOR2-  
230VAC  
WSMONITOR3  
WSMONITOR3-  
230VAC  
Figure 3. SCS WSMONITOR3 Constant Monitor  
Packaging  
WSMONITOR1 & WSMONITOR1-230VAC  
1 WSMONITOR1 Constant Monitor  
1 Power Adapter  
2 Screws  
1 Hook and Loop Fasteners  
1 Certificate of Calibration  
Description  
SCS Constant Monitors meet the Continuous Monitor  
requirements of ANSI/ESD S20.20. “Typical test  
programs recommend that wrist straps that are used  
daily should be tested daily. However, if the products  
that are being produced are of such value that  
knowledge of a continuous, reliable ground is needed,  
and then continuous monitoring should be considered  
or even required.” (ESD Handbook ESD TR20.20 Wrist  
Strap section 5.3.2.4.4 Test Frequency)  
WSMONITOR2 & WSMONITOR2-230VAC  
1 WSMONITOR2 Constant Monitor  
1 Mat Monitor Cord  
1 Power Adapter  
1 STACKJACK  
1 Alligator Clip  
2 Screws  
2 Hook and Loop Fasteners  
1 Certificate of Calibration  
Monitors can check up to two wrist strap systems  
and one worksurface, depending on the model.  
Compatible with single-wire wrist straps.  
Easy to use: Simply plug in the wrist strap.  
Easy to install: Attach the monitor boxes to the  
bench with included hardware, connect the mat and  
plug it in.  
WSMONITOR3 & WSMONITOR3-230VAC  
1 WSMONITOR3 Constant Monitor  
2 Operator Remotes  
1 Mat Monitor Cord  
1 Power Adapter  
1 STACKJACK  
1 Alligator Clip  
4 Screws  
2 Hook and Loop Fasteners  
1 Certificate of Calibration  
Damage to electronic devices is caused by static  
electricity from people. Connecting people to ground  
directs static electricity away from devices. Constant  
Monitors are designed to constantly test the connection  
of the person, the wristband and the coiled cord to help  
ensure that people remain grounded.  
SCS - 926 JR Industrial Drive, Sanford, NC 27332 • (919) 718-0000 • Website: StaticControl.com  
© 2015 DESCO INDUSTRIES, INC.  
Employee Owned  
TB-9036 Page 1 of 4 December 2015  
WSMONITOR3  
Installation  
1. Check that you have received all parts: monitor,  
remotes, four screws, power/ground adapter, mat  
cord and industrial hook and loop.  
WSMONITOR1  
1. Check that you have received all parts: monitor,  
power ground adapter and two mounting screws.  
2. Using the hook and loop, mount the monitor under  
2. Using the mounting screws, mount the monitor  
under the work bench. (Other suggested mounting  
locations include the bench top and under bench  
shelving.)  
the workbench shelf.  
3. Mount the remotes to the work bench with screws.  
4. Connect the monitor to the STACKJACK.  
3. Plug the power/ground adapter into the back of the  
5. Remove a plastic cap from STACKJACK and snap it  
to the mat.  
monitor and into a 3-prong 120VAC outlet.  
6. Connect the other mat snap to ground. (Cable not  
WORK BENCH  
included.)  
7. Plug the power/ground adapter into the back of the  
monitor and into a power outlet.  
MONITOR  
Note: The mat connection monitoring function can be  
connected to a workbench with a hard worksurface.  
AC ADAPTER  
SCREWS  
SHELF  
HOOK & LOOP  
WRIST STRAP  
STACKJACK  
MONITOR  
Figure 4. Installing the WSMONITOR1 Constant Monitor  
REMOVE CAP  
BENCH MAT  
WSMONITOR2  
1. Check that you have received all parts: monitor,  
power/ground adapter and two mounting screws.  
WORK BENCH  
(cable not  
included)  
REMOTE  
REMOTE  
2. Using the mounting screws, mount the monitor  
under the work bench. (Other suggested mounting  
locations include the bench top and under bench  
shelving.)  
WRIST STRAP  
AC ADAPTER  
WRIST STRAP  
3. Plug the power/ground adapter into the back of the  
monitor and into a 3-prong 120VAC outlet.  
Figure 6. Installing the WSMONITOR3 Constant Monitor  
STACKJACK  
Operation  
REMOVE CAP  
(cable not  
included)  
Place a wristband on your wrist and plug the  
coiled cord banana plug into the monitor’s banana  
jack. The monitor will display a green light when  
a functional wrist strap with good skin contact is  
connected to the unit.  
BENCH MAT  
WORK BENCH  
HOOK & LOOP  
The unit will sound an alarm and display a red light  
if the wrist strap becomes defective or if the person  
is not in contact with the wristband.  
AC ADAPTER  
MONITOR  
Unplug the wrist strap coiled cord from the unit to  
stop the alarm.  
Figure 5. Installing the WSMONITOR2 Constant Monitor  
Monitor will alarm if the continuity from the monitor  
to the mat to ground is lost.  
SCS - 926 JR Industrial Drive, Sanford, NC 27332 • (919) 718-0000 • Website: StaticControl.com  
© 2015 DESCO INDUSTRIES, INC.  
Employee Owned  
TB-9036 Page 2 of 4  
Calibration  
Safety Information  
The Constant Monitors are calibrated to standards  
traceable to NIST. Frequency of recalibratrion should  
be based on the critical nature of those ESD sensitive  
items handled and the risk of failure for the ESD  
protective equipment and materials. In general, we  
recommend that calibration be performed annually.  
Read, understand, and follow all safety information  
contained in these instructions prior to the use of  
Constant Monitors WSMONITOR1, WSMONITOR 2,  
and WSMONITOR3. Retain these instructions for future  
reference.  
Warning  
Use the SCS TMTOOL Verification Tester to perform  
periodic testing (once every 6-12 months) of the  
Constant Monitors. The Verification Tester can be  
used on the shop floor within a few minutes virtually  
eliminating downtime, verifying that the monitor is  
operating within tolerances.  
To reduce the risks associated with fire and explosion:  
Do not use in an explosive environment - monitor is  
not designed to be intrinsically safe.  
To reduce the risks associated with medical device  
malfunction:  
Persons with heart pacemaker devices should never  
use this monitor.  
To reduce the risks associated with hazardous voltage  
and fire:  
Use only the power supply provided by SCS and  
specified for the country of use.  
Do not position the monitor accessories or other  
equipment where unplugging the power supply is  
difficult.  
Always locate the power source (socket or outlet)  
near the equipment. The power supply plug serves  
as the disconnect device.  
Do not modify or attempt to service the power  
supply or monitor; there are no user serviceable  
parts.  
Do not use the power supply if damaged;  
Replace power supply if damaged using only SCS  
supplied parts.  
Figure 7. SCS TMTOOL Verification Tester  
Do not use the Constant Monitors WSMONITOR1,  
WSMONITOR 2, WSMONITOR3 or their power  
supplies outdoors in wet/humid environments.  
Do not use the Constant Monitors WSMONITOR1,  
WSMONITOR 2, WSMONITOR3 or their power  
supplies outside of the operating conditions listed in  
this user guide.  
Specifications  
Monitor Type  
Circuitry  
Impedence - single-wire  
Solid-state, surface mount  
Audible and visible (LED)  
8 megohms  
Alarm  
Alarm Threshold  
Power  
Always follow instructions for installation as stated in  
this user guide.  
120VAC, 230VAC  
Adjustments  
Calibration  
None required  
Caution  
To reduce the risks associated with environmental  
contamination:  
See SCS TMTOOL  
Dispose of this monitor in accordance with all  
applicable local and government regulations.  
Item  
Dimensions  
Weight  
WSMONITOR1 0.9" H x 1.8" W x 1.3" D  
WSMONITOR2 1.0" H x 2.4" W x 2.3" D  
WSMONITOR3 1.0" H x 4.0" W x 2.4" D  
1.2 oz.  
1.6 oz.  
2.6 oz.  
Notice  
To reduce the risk of ESD damage to components or  
assemblies being handled:  
Monitor must be checked periodically to verify each  
test mode is functioning correctly.  
Ensure proper operation of monitor by performing  
operational verification test as required.  
Ensure tester is properly grounded.  
SCS - 926 JR Industrial Drive, Sanford, NC 27332 • (919) 718-0000 • Website: StaticControl.com  
© 2015 DESCO INDUSTRIES, INC.  
Employee Owned  
TB-9036 Page 3 of 4  
Important Notice  
All statements, technical information, and  
Limited Warranty, Warranty Exclusions, Limit of  
Liability and RMA Request Instructions  
recommendations related to SCS’s products are  
based on information believed to be reliable, but the  
accuracy or completeness is not guaranteed. Before  
using this product, you must evaluate it and determine  
if it is suitable for your intended application. You  
assume all risks and liability associated with such use.  
Any statements related to the product which are not  
contained in SCS’s current publications, or any contrary  
statements contained on your purchase order shall  
have no force or effect unless expressly agreed upon, in  
writing, by an authorized officer of SCS.  
See the SCS Warranty -  
http://staticcontrol.descoindustries.com/warranty.aspx  
Made in China.  
SCS - 926 JR Industrial Drive, Sanford, NC 27332 • (919) 718-0000 • Website: StaticControl.com  
© 2015 DESCO INDUSTRIES, INC.  
Employee Owned  
TB-9036 Page 4 of 4  
厂商 型号 描述 页数 下载

TTELEC

WSM 模塑表面贴装绕线电阻器[ Moulded Surface Mount Wirewound Resistors ] 2 页

TTELEC

WSM1 模塑表面贴装绕线电阻器[ Moulded Surface Mount Wirewound Resistors ] 2 页

TTELEC

WSM16801FLFTR 模塑表面贴装绕线电阻器[ Molded Surface Mount Wirewound Resistor ] 3 页

TTELEC

WSM16801GLFTR 模塑表面贴装绕线电阻器[ Molded Surface Mount Wirewound Resistor ] 3 页

TTELEC

WSM16801JLFTR 模塑表面贴装绕线电阻器[ Molded Surface Mount Wirewound Resistor ] 3 页

TTELEC

WSM16801KLFTR 模塑表面贴装绕线电阻器[ Molded Surface Mount Wirewound Resistor ] 3 页

TTELEC

WSM2 模塑表面贴装绕线电阻器[ Moulded Surface Mount Wirewound Resistors ] 2 页

TTELEC

WSM26801FLFTR 模塑表面贴装绕线电阻器[ Molded Surface Mount Wirewound Resistor ] 3 页

TTELEC

WSM26801GLFTR 模塑表面贴装绕线电阻器[ Molded Surface Mount Wirewound Resistor ] 3 页

TTELEC

WSM26801JLFTR 模塑表面贴装绕线电阻器[ Molded Surface Mount Wirewound Resistor ] 3 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.165235s