Additional Resources: Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PYB30 │ DESCRIPTION: DC-DC CONVERTER
date 03/15/2021 │ page 2 of 7
PART NUMBER KEY
PYB30 - QXX - XXX
Base Number
Output Voltage
Input Voltage
Output
S = single
D = dual
T = triple
INPUT
parameter
conditions/description
min
typ
max
units
24 Vdc input models
48 Vdc input models
9
18
24
48
36
75
Vdc
Vdc
operating input voltage
start-up voltage
24 Vdc input models
48 Vdc input models (single/dual output models)
48 Vdc input models (triple output models)
9
18
17.8
Vdc
Vdc
Vdc
24 Vdc input models
48 Vdc input models
7.8
16
Vdc
Vdc
under voltage shutdown1
surge voltage
for maximum of 1 second
24 Vdc input models
48 Vdc input models
-0.7
-0.7
50
100
Vdc
Vdc
start-up time
10
1
ms
filter
pi filter
models ON (CTRL open or connect high level, 2.5~12 Vdc)
models OFF (CTRL connect GND or low level, 0~1.2 Vdc)
input current (models OFF)
CTRL2
mA
Notes:
1. Contact CUI if you are planning to use this feature in your application.
2. CTRL pin voltage is referenced to GND.
OUTPUT
parameter
conditions/description
min
typ
max
units
full load, input voltage from low to high
single and dual output models
triple output models (main output)
triple output models (auxiliary outputs)
±0.2
±0.5
±1
±5
%
%
%
line regulation
load regulation3
5% to 100% load, nominal input
single and dual output models
triple output models (main output)
triple output models (auxiliary outputs)
±0.5
±1
±2
±5
%
%
%
dual output models:
main output 50% load, secondary output from
10% to 100% load
cross regulation
voltage accuracy
±5
%
single and dual output models
triple output models (main output)
triple output models (auxiliary outputs)
±1
±1
±3
±3
±3
±5
%
%
%
adjustability4
±10
400
300
±3
%
kHz
μs
switching frequency
transient recovery time
transient response deviation
PWM mode
25% load step change
25% load step change
500
±5
%
100% load, single and dual output models
100% load, triple output models
±0.02
±0.03
%/°C
%/°C
temperature coefficient
Notes:
3. For dual output models, unbalanced load can not exceed ±5%. If ±5% is exceeded, it may not meet all specifications.
4. Output trimming available on single and dual output models only.
cui.com