PYB10-Q48-S12-U

型号:

PYB10-Q48-S12-U

品牌:

CUI[ CUI INC ]

页数:

6 页

PDF大小:

349 K

Additional Resources: Product Page  
|
3D Model  
date 08/16/2013  
page 1 of 6  
SERIES: PYB10-T & PYB10-U DESCRIPTION: DC-DC CONVERTER  
FEATURES  
• up to 10 W isolated output  
• industry standard pinout  
• 4:1 input range (9~36 V, 18~75 V)  
• smaller package  
• single/dual regulated outputs  
• 1,500 Vdc isolation  
• continuous short circuit, over voltage protection  
• reverse polarity protection on chassis mount (-T) option  
• temperature range (-40~85°C)  
• six-sided metal shielding  
• efficiency up to 88%  
input  
voltage  
output  
voltage  
output  
current  
output  
power  
max  
ripple  
efciency2  
MODEL  
and noise1  
typ  
range  
min  
max  
max  
typ  
(Vdc)  
(Vdc)  
(Vdc)  
3.3  
5
(mA)  
(mA)  
2400  
2000  
833  
(W)  
(mVp-p)  
(%)  
PYB10-Q24-S3  
PYB10-Q24-S5  
PYB10-Q24-S12  
PYB10-Q24-S15  
PYB10-Q24-S24  
PYB10-Q24-D5  
PYB10-Q24-D12  
PYB10-Q24-D15  
PYB10-Q48-S3  
PYB10-Q48-S5  
PYB10-Q48-S12  
PYB10-Q48-S15  
PYB10-Q48-S24  
PYB10-Q48-D5  
PYB10-Q48-D12  
PYB10-Q48-D15  
24  
24  
24  
24  
24  
24  
24  
24  
48  
48  
48  
48  
48  
48  
48  
48  
9~36  
120  
100  
42  
8
80  
80  
80  
80  
80  
80  
80  
80  
80  
80  
80  
80  
80  
80  
80  
80  
79  
82  
86  
87  
87  
83  
86  
88  
79  
82  
86  
87  
87  
83  
86  
88  
9~36  
10  
10  
10  
10  
10  
10  
10  
8
9~36  
12  
9~36  
15  
33  
667  
9~36  
24  
21  
416  
9~36  
±5  
±12  
±15  
3.3  
5
±50  
±21  
±16  
120  
100  
42  
±1000  
±416  
±333  
2400  
2000  
833  
9~36  
9~36  
18~75  
18~75  
18~75  
18~75  
18~75  
18~75  
18~75  
18~75  
10  
10  
10  
10  
10  
10  
10  
12  
15  
33  
667  
24  
21  
416  
±5  
±12  
±15  
±50  
±21  
±16  
±1000  
±416  
±333  
Notes:  
1. Ripple and noise are measured at 20 MHz BW by “parallel cable” method  
2. Efciency is approximately 2% lower for Chassis Mount (-T) models.  
PART NUMBER KEY  
PYB10 - QXX - XXX - X  
Base Number  
Mounting Type  
T = Chassis mount  
U = U-Frame  
Input Voltage  
Output Voltage  
Output  
S = single  
D = dual  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: PYB10-T & PYB10-U DESCRIPTION: DC-DC CONVERTER  
date 08/16/2013 page 2 of 6  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
24 V input models  
48 V input models  
9
18  
24  
48  
36  
75  
Vdc  
Vdc  
operating input voltage  
start-up voltage  
24 V input models  
48 V input models  
9
18  
Vdc  
Vdc  
for maximum of 1 second  
24 V input models  
48 V input models  
surge voltage  
-0.7  
-0.7  
50  
100  
Vdc  
Vdc  
lter  
pi lter  
models ON (CTRL open or connect high level, 3.5-12 Vdc)  
models OFF (CTRL connect GND or low level, 0-1.2 Vdc)  
input current (models OFF)  
CTRL1  
1
3
mA  
Note:  
1. CTRL pin voltage is referenced to GND.  
OUTPUT  
parameter  
conditions/description  
full load, input voltage from low to high  
5% to 100% load  
min  
typ  
max  
±0.5  
±1  
units  
%
line regulation  
load regulation  
±0.2  
±0.5  
%
dual output models:  
main output 50% load, secondary output from  
10% to 100% load  
cross regulation  
±5  
%
voltage accuracy  
voltage balance2  
±1  
±0.5  
350  
300  
±3  
±2  
%
%
dual output, balanced loads  
PWM mode  
±1.5  
switching frequency  
transient recovery time  
transient response deviation  
temperature coefcient  
KHz  
μs  
25% load step change  
25% load step change  
100% load  
500  
±5  
%
±0.03  
%/°C  
Note:  
2. For dual output models, unbalanced load can not exceed ±5%. If ±5% is exceeded, it may not meet all specications.  
PROTECTIONS  
parameter  
conditions/description  
min  
typ  
max  
units  
short circuit protection  
over voltage protection  
continuous, automatic recovery  
110  
120  
140  
%Vo  
SAFETY AND COMPLIANCE  
parameter  
conditions/description  
min  
typ  
max  
units  
Vdc  
isolation voltage  
isolation resistance  
conducted emissions  
radiated emissions  
ESD  
for 1 minute at 1 mA max.  
at 500 Vdc  
1,500  
1,000  
MΩ  
CISPR22/EN55022, class A, class B (external circuit required, see Figure 1-b)  
CISPR22/EN55022, class A, class B (external circuit required, see Figure 1-b)  
IEC/EN61000-4-2, class B, contact ± 4kV  
radiated immunity  
EFT/burst  
IEC/EN61000-4-3, class A, 10V/m  
IEC/EN61000-4-4, class B, ± 2kV (external circuit required, see Figure 1-a)  
IEC/EN61000-4-5, class B, ± 2kV (external circuit required, see Figure 1-a)  
IEC/EN61000-4-6, class A, 3 Vr.m.s  
surge  
conducted immunity  
voltage dips & interruptions  
MTBF  
IEC/EN61000-4-29, class B, 0%-70%  
as per MIL-HDBK-217F @ 25°C  
yes  
1,000,000  
hours  
RoHS compliant  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: PYB10-T & PYB10-U DESCRIPTION: DC-DC CONVERTER  
date 08/16/2013 page 3 of 6  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
typ  
max  
85  
units  
°C  
operating temperature  
storage temperature  
storage humidity  
case temperature  
vibration  
see derating curve  
-40  
-55  
5
125  
95  
°C  
non-condensing  
%
at full load, Ta=71°C  
105  
°C  
10~55 Hz for 30 min. along X, Y and Z axis  
10  
G
MECHANICAL  
parameter  
conditions/description  
min  
typ  
max  
units  
chassis mount: 76.0 x 31.5 x 21.2  
U-Frame: 52.32 x 54.99 x 19.05  
mm  
mm  
dimensions  
case material  
weight  
aluminum alloy  
chassis mount  
U-Frame  
44  
58  
g
g
MECHANICAL DRAWING  
CHASSIS MOUNT  
units: mm[inch]  
tolerance: ±0.5[±0.020]  
4
5
6
1
2
3
Wire range: 24~12 AWG  
PIN CONNECTIONS  
Single  
Output  
Dual  
Output  
PIN  
Top View  
1
2
3
4
5
6
CTRL  
GND  
Vin  
CTRL  
GND  
Vin  
0V  
-Vo  
NC  
0V  
+Vo  
+Vo  
Front View  
U-FRAME  
units: mm[inch]  
tolerance: ±0.5[±0.020]  
54.99 2.165  
20.32 0.800  
0.010 (2 PLCS)  
0.079 X 0.157  
4.75 0.187  
(2 PLCS)  
3.51 0.138  
(2 PLCS)  
R1.76 0.069  
(2 PLCS)  
[2.01 X 3.99]  
(2 PLCS)  
Wire range: 22~14 AWG  
DIN rail mounting kit available  
(part# STK-DIN)  
34.93 1.375  
0.010  
34.01 1.339  
0.010  
52.32 2.060  
PIN CONNECTIONS  
Single  
Output  
Dual  
Output  
PIN  
1
2
3
4
5
6
7
8
9.16 0.361  
0.010  
12.19 0.480  
1
2
3
4
5
6
7
8
GND  
Vin  
GND  
Vin  
5.31 0.209  
(5 PLCS)  
M3X4  
(5 PLCS)  
33.02 1.300  
0.010 (2 PLCS)  
5.21 0.205  
(2 PLCS)  
Top View  
CTRL  
Case  
NC  
CTRL  
Case  
NC  
10.99 0.433  
0.010 (2 PLCS)  
1.00 0.039  
(TYP)  
52.99 2.086  
Bottom View  
19.05 0.750  
+Vo  
NC  
+Vo  
0V  
4.01 0.158  
0.010 (TYP)  
0V  
-Vo  
Front View  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: PYB10-T & PYB10-U DESCRIPTION: DC-DC CONVERTER  
date 08/16/2013 page 4 of 6  
DERATING CURVES  
Temperature Derating Curve  
100  
80  
60  
Safe operating area  
40  
20  
-40  
-20  
0
20  
40  
60 71  
85  
Ambient Temperature (°C)  
EMC RECOMMENDED CIRCUIT  
CY2  
FUSE  
V in  
+Vo  
Vin  
LDM1  
LDM2  
+
LOAD  
Figure 1  
EUT  
C1  
MOV  
TVS  
C0  
-Vo  
(0V)  
GND  
GND  
CY1  
(b)  
(a)  
Table 1  
Recommended external circuit components  
Vin (Vdc) 24 48  
Choose according to input current  
FUSE  
MOV  
LDM1  
TVS  
C0  
S14K35  
56μH  
S14K60  
56μH  
SMCJ48A  
330μF/50V  
1μF/50V  
4.7μH  
SMCJ90A  
330μF/100V  
1μF/100V  
4.7μH  
C1  
LDM2  
CY1  
CY2  
1 nF/2 KV  
1 nF/2 KV  
1 nF/2 KV  
1 nF/2 KV  
TEST CONFIGURATION  
Table 2  
External components  
Oscilloscope  
Lin  
Lin  
4.7μH  
Current  
Probe  
Figure 2  
220μF, ESR < 1.0Ω  
Load  
Cin  
DC  
DC  
Cin  
at 100 KHz  
Note:  
Input reected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate source impedance.  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: PYB10-T & PYB10-U DESCRIPTION: DC-DC CONVERTER  
date 08/16/2013 page 5 of 6  
APPLICATION NOTES  
1. Recommended circuit  
This series has been tested according to the following recommended testing circuit before leaving the factory. This series should be  
tested under load (see Figure 3). If you want to further decrease the input/output ripple, you can increase the capacitance accord-  
ingly or choose capacitors with low ESR (see table 3). However, the capacitance of the output lter capacitor must be appropriate. If  
the capacitance is too high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the  
maximum capacitance must be less than the maximum capacitive load (see Table 4).  
Figure 3  
Dual Output  
Vin  
Single Output  
Vin  
+Vo  
0V  
+Vo  
0V  
Cout  
Cout  
Cout  
Cin  
DC  
Cin  
DC  
DC DC  
GN D  
GN D  
-Vo  
Table 3  
Table 4  
Max.  
Capacitive  
Load  
Max.  
Capacitive  
Load4  
Vin  
(Vdc)  
Cin  
(F)  
Cout  
(F)  
Single  
Vout  
(Vdc)  
Dual  
Vout  
(Vdc)  
24  
48  
10~47  
10~47  
10  
10  
(μF)  
(μF)  
3.3  
5
2200  
2200  
4701  
3302  
100  
--  
5
--  
680  
2203  
100  
--  
12  
12  
15  
--  
15  
24  
Notes:  
1. 330 μF for 48Vin.  
2. 220 μF for 48Vin.  
3. 150 μF for 48Vin.  
4. For each output.  
Note:  
1. Minimum load shouldn't be less than 5%, otherwise ripple may increase dramatically. Operation under minimum load will not damage the converter, however, they may  
not meet all specications listed.  
2. Maximum capacitive load is tested at input voltage range and full load.  
3. All specications are measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specied.  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: PYB10-T & PYB10-U DESCRIPTION: DC-DC CONVERTER  
date 08/16/2013 page 6 of 6  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
updated spec  
06/26/2013  
08/16/2013  
1.01  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical  
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to  
affect its safety or effectiveness.  
厂商 型号 描述 页数 下载

CUI

PYB10 DC-DC变换器[ DC-DC CONVERTER ] 6 页

CUI

PYB10-DIN [ DC-DC CONVERTER ] 6 页

CUI

PYB10-Q24-D12 DC-DC变换器[ DC-DC CONVERTER ] 6 页

CUI

PYB10-Q24-D12-DIN [ DC/DC CONVERTER +/-12V 10W DIN ] 6 页

CUI

PYB10-Q24-D15 DC-DC变换器[ DC-DC CONVERTER ] 6 页

CUI

PYB10-Q24-D15-DIN [ DC/DC CONVERTER +/-15V 10W DIN ] 6 页

CUI

PYB10-Q24-D5 DC-DC变换器[ DC-DC CONVERTER ] 6 页

CUI

PYB10-Q24-D5-DIN [ DC/DC CONVERTER +/-5V 10W DIN ] 6 页

CUI

PYB10-Q24-S12 DC-DC变换器[ DC-DC CONVERTER ] 6 页

CUI

PYB10-Q24-S12-DIN [ DC/DC CONVERTER 12V 10W DIN ] 6 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.220490s