PYX28HC64 - 8K x 8 EEPROM
MAꢃIMUM RATIꢀꢂS(1)
RECOMMEꢀDED OPERATIꢀꢂ COꢀDITIOꢀS
Sym Parameter
Value
Unit
ꢂrade(2)
Ambient Temp
ꢂꢀD
VCC
Power Supply Pin with
VCC
Military
-55°C to +125°C
0V
5.0V ± 10%
-0.3 to +6.25
V
Respect to GND
Terminal Voltage with
VTERM Respect to GND (up to
7.0V)
-0.5 to +6.25
V
CAPACITAꢀCES(4)
TA
Operating Temperature
-55 to +125
-55 to +125
-65 to +150
1.0
°C
°C
°C
W
(VCC = 5.0V, TA = 25°C, f = 1.0MHz)
TBIAS Temperature Under Bias
TSTG Storage Temperature
Sym Parameter
Conditions Typ Unit
PT
Power Dissipation
CIN
Input Capacitance
VIN = 0V
10
10
pF
pF
IOUT DC Output Current
50
mA
COUT
Output Capacitance
VOUT = 0V
DC ELECTRICAL CHARACTERISTICS
(Over Recommended Operating Temperature & Supply Voltage)(2)
Sym Parameter
Test Conditions
Min
Max
Unit
V
VIH Input High Voltage
2.0
VCC + 0.5
0.8
VIL Input Low Voltage
-0.5(3)
V
VHC CMOS Input High Voltage
VLC CMOS Input Low Voltage
VOL Output Low Voltage (TTL Load)
VOH Output High Voltage (TTL Load)
VCC - 0.2 VCC + 0.5
V
-0.5(3)
0.2
0.4
V
IOL = +5 mA, VCC = Min
IOH = -5 mA, VCC = Min
V
2.4
-10
V
VCC = Max
ILI
Input Leakage Current
+10
+10
µA
µA
VIN = GND to VCC
VCC = Max, CE = VIH,
VOUT = GND to VCC
CE ≥ VIH, OE = VIL,
VCC = Max,
-10
—
ILO Output Leakage Current
ISB Standby Power Supply Current (TTL Input Levels)
3
mA
µA
f = Max, Outputs Open
CE ≥ VHC,
VCC = Max,
—
—
ISB1 Standby Power Supply Current (CMOS Input Levels)
250
f = Max, Outputs Open,
VIN ≤ VLC or VIN ≥ VHC
CE = OE = VIL,
WE = VIH,
ICC Supply Current
40
µA
All I/O's = Open,
Inputs = VCC = 5.5V
ꢀotes:
1. Stresses greater than those listed under MAXIMUM RATINGS may
cause permanent damage to the device. This is a stress rating only
and functional operation of the device at these or any other conditions
above those indicated in the operational sections of this specification
is not implied. Exposure to MAXIMUM rating conditions for extended
periods may affect reliability.
3.TransientinputswithVIL andIIL notmorenegativethan-3.0Vand-100mA,
respectively, are permissible for pulse widths up to 20ns.
4. This parameter is sampled and not 100% tested.
2. Extended temperature operation guaranteed with 400 linear feet per
minute of air flow.
Document # EEPROM107 REV OR
Page 2