AZ762
CONTACTS
Rated Load
VDE
Rated Load
1 Form A - DC coil
UL, CUR 1 Form A / 1 Form C
16 A at 250 VAC, 50k cycles, 85°C [3]
16 A at 250 VAC, 20k cycles, 85°C [2]
16 A at 250 VAC, 30k cycles, 70°C [1]
12.5 A at 400 VAC, 30k cycles, 85°C [3]
10 A at 250 VAC, 100k cycles, 70°C [1]
9 A at 250 VAC, cos phi 0.4, 120k cycles, 70°C
[1][2][3]
16 A at 277 VAC, Resistive, 100k cycles, 85°C [3]
16 A at 277 VAC, Resistive, 75k cycles, 85°C [2]
16 A at 277 VAC, Resistive, 50k cycles, 85°C [1]
12 A at 277 VAC, Resistive, 100k cycles, 40°C, (N.O.) [1]
9.2 A at 120 VAC, General use, 100k cycles, 60°C [2]
9 A at 250 VAC, Resistive, 100 k cycles, 105°C [1]
8.2 A at 120 VAC, Resistive, 100k cycles, 60°C [2]
4 A at 347 VAC, General use, 6k cycles, 85°C, (N.C.) [1]
5 FLA / 30 LRA at 250 VAC, 30k cycles, 65°C [2]
5 FLA / 30 LRA at 250 VAC, 30k cycles, 65°C [3] *
1 HP at 250 VAC, 85°C [1]
6 A at 400 VAC, 100k cycles, 85°C [3]
1 Form A - DC coil - high inrush version “I”
16 A at 250 VAC, 30k cycles, 85°C [2]
16 A at 400 VAC, 10k cycles, 85°C [2]
1 HP at 277 VAC, 40°C, (N.O.) [1]
1/2 HP at 250 VAC, 85°C [2]
1 Form A - DC coil sensitive
1/2 HP at 125 VAC, 85°C [1]
1/3 HP at 125 VAC, 85°C [2]
10 A at 250 VAC, 100k cycles, 85°C [1]
10 A at 250 VAC, 20k cycles, 85°C [2]
6 A at 400 VAC, 100k cycles, 85°C [1]
TV-5, 125 VAC, 85°C [1]
B300, 85°C [2]
R300, 85°C [2]
1 Form A - AC coil
16 A at 250 VAC, 50k cycles, 70°C [3]
* approved for Class F version only
1 Form C - DC coil
1 Form A - DC coil (without gold plating)
20 A at 277 VAC, Resistive, 40°C [2]
10 FLA / 60 LRA at 250 VAC, 40°C [2]
5 FLA / 30 LRA at 250 VAC, 30k cycles, 85°C [2]
1 HP at 250 VAC, 30k cycles, 40°C [2]
1/2 HP at 125 VAC, 30k cycles, 40°C [2]
16 A at 250 VAC, 20k cycles, 85°C [2]
16 A at 250 VAC, 30k cycles, 70°C [1]
12 A at 250 VAC, 50k cycles, 85°C [3]
16 A at 250 VAC, 10k cycles, 85°C [3] *
9 A at 250 VAC, cos phi 0.4, 120k cycles, 70°C
[1][2][3] *
TV-5, 120 VAC, 40°C [2]
* change-over contact tested as make contact
1 Form A - DC coil - high inrush version “I”
16 A at 250 VAC, General use, 75k cycles, 40°C [2]
1 Form C - DC coil sensitive
10 A at 250 VAC, 70k cycles, 85°C [1]
10 A at 250 VAC, 20k cycles, 85°C [2]
6 A at 400 VAC, 70k cycles, 85°C [1]
1 Form C - AC coil
16 A at 250 VAC, 20k cycles, 70°C [3]
RELAY ORDERING DATA
DC COIL SPECIFICATIONS – STANDARD COIL
ORDER NUMBER*
Nominal Coil
VDC
Must Operate
VDC
Max. Continuous
VDC
Coil Resistance
Ohm ± 10%
1 Form C
1 Form A
5
6
3.5
4.2
10.2
12.3
18.3
24.7
37.0
49.4
98.0
112.9
206.9
62
90
AZ762–1A–5D
AZ762–1A–6D
AZ762–1A–9D
AZ762–1A–12D
AZ762–1A–18D
AZ762–1A–24D
AZ762–1A–48D
AZ762–1A–60D
AZ762–1A–110D
AZ762–1C–5D
AZ762–1C–6D
AZ762–1C–9D
AZ762–1C–12D
AZ762–1C–18D
AZ762–1C–24D
AZ762–1C–48D
AZ762–1C–60D
AZ762–1C–110D
9
6.3
200
12
18
24
48
60
110
8.4
360
12.6
16.8
33.6
42.0
77.0
810
1,440
5,760
7,500
25,200
*
“1A” or “1C” denote silver cadmium oxide contacts.
Add suffix “E” to “1A” or “1B” or “1C” for silver tin oxide contacts.
Add suffix “B” to “1A” or “1B” or “1C” for silver nickel contacts.
Add suffix “E” at the end of order number for sealed version.
Add suffix “A” at the end of order number for gold plated contacts.
Add suffix “I” at the end of part number for high inrush version 80 A (contact form “1AE” only, no gold plating).
Add suffix “F” at the end of order number for Class F version.
ZETTLER electronics GmbH
Junkersstr. 3, D-82178 Puchheim, Germany
phone: +49 89 800 97-0 office@ZETTLERelectronics.com
fax:
+49 89 800 97-200 www.ZETTLERelectronics.com
This product specification to be used only together with the application notes
2014-01-29
which can be downloaded from http://www.ZETTLERelectronics.com/pdfs/relais/ApplicationNotes.pdf