MZS-SERIES
Ⅵ Features
(1) Attenuation effect against high voltage pulse
noise
(2) For equipment designed to conform EMI
regulations such as VCCI, CISPR, FCC, VDE,
etc.
(3) Attenuates conductive emission from power
supply
(4) Leakage current: 1mA max. (250V, 60Hz)
(5) High shielded effect
MZS-1215
MZS-1220
Ⅵ Safety standard
UL1283,
CSA Std. C22. 2 No. 8
VDE0565 Teil. 3
VDE0565 will transfer to EN133200
on and after July 23, 2003.
MZS-1206
(
)
MZS-1210
Ⅵ Specifications
Model
(Note)
MZS-1206-33
6A
MZS-1210-33
10A
MZS-1215-33
15A
MZS-1220-33
20A
Item
1
2
3
4
Rated voltage (AC, DC)
Rated current (AC, DC)
250V
Test voltage (terminal to case, AC 1 minute)
Isolation resistance (terminal to case, 500VDC)
2500V
100MΩ min.
0.5mA max.
1mA max.
125V, 60Hz
5
Leakage current
250V, 60Hz
6
7
8
9
DC resistance
0.10Ω max.
0.05Ω max.
0.03Ω max.
0.02Ω max.
Temperature rise
30°C max.
–25 ~ +85°C
310g
Operating temperature range
Weight
(typ)
<
(Note) : Value at Ta 55°C. Refer to the derating curve shown below at Ta > 55°C.
=