Pulse Transformers
IX
www.schurter.com/pg85
Cost optimized pulse transformer for THT mounting, up to 2W
Description
Applications
-ꢀGalvanicꢀseparationꢀofꢀdrive-ꢀandꢀpower-circuit
-ꢀHighꢀinsulationꢀratingꢀ(>2.2ꢀkVAC)ꢀbetweenꢀtheꢀprimaryꢀandꢀtheꢀsecon-
daryꢀwindings
-ꢀMainlyꢀusedꢀinꢀignitionꢀcircuitsꢀwithꢀThyristors,ꢀTriacs,ꢀpowerꢀtransistorsꢀ
andꢀIGBT's
-ꢀSmallꢀcouplingꢀcapacitancesꢀbetweenꢀprimaryꢀandꢀsecondaryꢀwindingsꢀ
limitꢀtransientꢀfeedbackꢀfromꢀtheꢀpowerꢀsupplyꢀsideꢀtoꢀtheꢀcontrolꢀelec-
-ꢀDC/DCꢀconverters
tronics
-ꢀLineꢀcouplingꢀtransformersꢀinꢀhighꢀspeedꢀdataꢀtransmission
-ꢀCostꢀoptimizedꢀdesign
-ꢀTheꢀdefinedꢀpartialꢀdischargeꢀvoltageꢀguaranteesꢀanꢀeffecivelyꢀunlimitedꢀ
serviceableꢀlive
References
GeneralꢀProductꢀInformation
Weblinks
Standards
-ꢀVDEꢀ110b
Approvals,ꢀRoHS,ꢀCHINA-RoHS,ꢀe-Store,ꢀDistributor-Stock-Check
Technical Data
Ratedꢀvoltage
upꢀtoꢀ500ꢀVAC
500ꢀVµs
0.7ꢀ-ꢀ0.8ꢀµs
1:1:1,ꢀ3:1:1
THTꢀ
ClimaticꢀCategory
AllowableꢀOperationꢀTemp.
25/100/21ꢀacc.ꢀtoꢀIECꢀ60068-1
-25ꢀ°Cꢀtoꢀ100ꢀ°C
VoltageꢀTimeꢀIntegral
PulseꢀRiseꢀTime
TurnsꢀRatio
Terminalꢀtechnic
Weight
ꢀ34ꢀg
Material:ꢀHousing
SealingꢀCompound
Plasticsꢀ
ULꢀ94V-0ꢀ
Dimensions
Case 13-8
max. 25.5
7.5
max. 25.5
7.5
(0.4)
min. 5
1)
1) Prim.
Variants
Turns Ratio
T [μs]
Iign [A] UVAC [V]
Uisol
[kV]
Us x Tw Ls [mH]
[Vμs]
RP [Ω]
RS [Ω]
CC [pF]
Pm [W] Weight [g] Packing unit [pcs.]
Housing
Order Number
r
1:1:1
0.8
1.0
380
2.5
500
3.0
0.3
0.3
40
2.0
34
60
13-8
IX-30-0001
Theꢀspecifications,ꢀdescriptionsꢀandꢀillustrationsꢀindicatedꢀinꢀthisꢀdocumentꢀareꢀbasedꢀonꢀ