The VTX-5786B pulsed-coupled cavity TWT covers 8.6 GHz to 9.5 GHz with 12 kW peak output power,
2.0 % duty cycle. This device has a non-intercepting grid pulsed and single stage depressed collector to achieve
48 dB gain.
Custom configurations are also available. These variations in the performance and configuration include: cooling
method (affects average power level), mechanical configuration, electrical and RF connections, & multiple stage
depressed collector.
Typical Operating Parameters
Features
PARAMETER
Cathode Voltage
Cathode Current
Heater Voltage
Heater Current
Collector Voltage
Grid Bias Voltage
Grid Pulse Voltage
RF Drive Power
Pulse Width
MIN
-25
---
MAX
-22
4.5
11
4
17
-300
450
0.16
50
UNITS
kV
a
V
A
kV
V
v
W
µsec
%
•
•
•
•
•
•
•
•
•
8.6 GHz to 9.5 GHz
12 kW PEAK OUTPUT POWER
2.0% DUTY CYCLE
NON-INTERCEPTING GRID PULSED
48 dB GAIN
SINGLE STAGE DEPRESSED COLLECTOR
FORCED AIR COOLED
9
---
14
-400
300
---
---
---
2.0
---
---
PPM FOCUSED
WR 90 WAVEGUIDE, INPUT AND OUTPUT
Duty Cycle
2.0
---
3
lbm/min
Cooling Flow Rate
Pressure Drop
Weight
In H2O
lbs
20
5 X5X 20
Dimensions
---
inches
The values listed above represent specified limits for the product and are subject to change. The data should be used
for basic information only. Formal, controlled specifications may be obtained from CPI for use in equipment design.
For additional information on CPI MPP products contact:
CPI MPP, Coupled Cavity TWT Operation - 3120 Hansen Way, Palo Alto, CA 94303-0750