4WTR-B

型号:

4WTR-B

描述:

烟雾探测器用探测仪和继电器选项[ Smoke Detectors with Sounder and Relay Option ]

品牌:

SYSTEMSENSOR[ SYSTEMSENSOR ADVANCED IDEAS. ]

页数:

2 页

PDF大小:

184 K

Smoke Detectors with  
Sounder and Relay Option  
System Sensor i3sounder and relay smoke detectors  
apply the guiding principles of installation ease,  
intelligence, and instant inspection in a series of  
specialty conventional devices.  
Installation ease. Throughout the i3 series, installation is simple  
with its installer-friendly base and plug-in design. The base  
accommodates a broad range of back box and direct mounting  
options and provides ample space for pre-wiring the device. To  
complete the installation, the i3 detector plugs into its base with a  
simple Stop Drop ’N Lock action.  
Features  
• 85 dB sounder  
• Form C relay  
• Isolated thermal sensor  
• Plug-in design – base included  
• In-line terminals  
Intelligence. To reduce the likelihood of nuisance alarms, all  
i3 detectors are equipped with both drift compensation and  
smoothing algorithms. These capabilities minimize both short- and  
long-term causes of nuisance alarms such as RF interference and  
dust accumulation. When connected to the 2W-MOD2 loop test/  
maintenance module or an i3 Readypanel, 2-wire i3 detectors can  
generate a remote maintenance signal when in a maintenance or  
freeze trouble condition. To measure the sensitivity of any i3 detector,  
the SENS-RDR displays the reading, in terms of percent-per-foot  
obscuration, within seconds.  
• Flexible mounting options  
• Stop-Drop ’N Lockattachment to the base  
• Removable cover and chamber  
• Remote maintenance signaling  
• Drift compensation and smoothing algorithms  
• Simplified sensitivity measurement  
• Dual color LEDs  
Instant inspection. The i3 line’s red and green LEDs simplify local  
status indication during power-up, standby, alarm, maintenance and  
freeze trouble conditions. When in alarm, i3 sounder models generate  
an 85 dB temporal tone. If connected to the RRS-MOD reversing  
relay/synchronization module, all i3 sounders on the loop will  
activate when one detector is in alarm. Additionally, the RRS-MOD  
synchronizes the output of all i3 sounders to ensure a clear audible  
signal.  
Agency Listings  
Should the application call for differentiating between a local and  
a general alarm, the i3 line offers an isolated thermal model, which  
initiates a local alarm when smoke is detected, and a general alarm  
when the thermal sensor is activated.  
S911  
ꢀ015195  
7272-165ꢀ:164  
ꢀ72-02-E  
21ꢀꢀ  
Smoke Detector Specifications  
Electrical Specifications  
LED Modes  
LED Mode  
Power up  
Operating Voltage  
Nominal: 12/24 V non-polarized  
2-wire: 8.5 V - ꢀ5 V  
Green LED Red LED  
Condition  
Duration  
Blink every Blink every 10 Initial LED  
80 seconds  
4-wire: 10 V - ꢀ5 V  
10 seconds seconds  
status  
Maximum Ripple Voltage ꢀ0% of applied voltage (peak to peak)  
indication  
Standby Current  
2-wire: 50 µA maximum average  
4-wire: 50 µA maximum average  
Normal  
(standby)  
Blink every 5 off  
seconds  
Peak Standby Current  
Maximum Alarm Current  
2-wire: 100 µA  
4-wire: n/a  
Out of  
sensitivity  
off  
off  
off  
Blink every 5  
seconds  
2-wire: 2WTR-B: 1ꢀ0 mA limited by control  
panel  
2WTA-B: 1ꢀ0 mA**  
4-wire: 4WTA-B, 4WTR-B: ꢀ5 mA  
4WTAR-B, 4WITAR-B: 50 mA  
**Direct Power (Non-reverse Polarity): 1ꢀ0  
mA limited by panel. Reverse Polarity Power:  
ꢀ0 mA for the 2WTA-B in alarm; 12 mA for all  
other 2WTA-B units on the loop. Add 25 mA  
for the RRS-MOD reversing relay alarm current.  
Freeze  
trouble  
Blink every 10  
seconds  
Alarm  
Solid  
Power Up Sequence for LED Indication  
Condition  
Duration  
Initial LED  
status  
indication  
80 seconds  
Architect/Engineer Specifications  
Alarm Contact Ratings  
2-wire: n/a  
4-wire: 0.5 A @ ꢀ0V AC/DC  
Smoke detector shall be a System Sensor i3 Series model number_______,  
listed to Underwriters Laboratories UL 268 for Fire Protection Signaling  
Systems. The detector shall be a combination photoelectric/thermal  
equipped with a sounder (model 2WTA-B, 4WTA-B), a Form C relay (model  
2WTR-B), a combination sounder/relay (model 4WTAR-B) or an isolated  
thermal/sounder/relay (model 4WITAR-B). The detector shall include a  
mounting base for mounting to ꢀ½-inch and 4-inch octagonal, single gang,  
and 4-inch square back boxes with a plaster ring, or direct mount to the  
ceiling using drywall anchors. Wiring connections shall be made by means  
of SEMS screws. The detector shall allow pre-wiring of the base and the  
head shall be a plug-in type. The detector shall have a nominal sensitivity  
of 2.5% per foot nominal as measured in the UL smoke box. The detector  
shall be capable of automatically adjusting its sensitivity by means of drift  
compensation and smoothing algorithms. The detector shall provide dual  
color LED indication which blinks to indicate power-up, normal standby, out  
of sensitivity, alarm, and freeze trouble conditions. When used in conjunction  
with the 2W-MOD2 module, 2-wire models shall include a maintenance  
signal to indicate the need for maintenance at the alarm control panel, and  
shall provide a loop testing capability to verify the circuit without testing each  
detector individually. When used in conjunction with the RRS-MOD module,  
all isounder models on a loop shall sound when one alarms, all shall be  
synchronized, and all sounders may be silenced from the panel.  
Form C Contact Ratings  
2A @ ꢀ0V AC/DC  
Physical Specifications  
Operating Temperature  
Range  
ꢀ2°F–100° F (0°C–ꢀ7.8° C)  
Operating Humidity  
Range  
0 to 95% RH non-condensing  
Thermal Sensor  
Freeze Trouble  
Sensitivity  
1ꢀ5° F (57.2° C) fixed  
41° F (5° C)  
2.5%/ft. nominal  
14–22 AWG  
Input Terminals  
Dimensions (including  
base)  
5.ꢀ inches (1ꢀ4 mm) diameter, 2.0 inches (51  
mm) height  
Approximate Weight  
7.1 oz. (200 grams)  
Sound Pressure Output  
85 dBA (models 2WTA-B, 4WTA-B, 4WTAR-B,  
and 4WITAR-B only)  
Mounting  
ꢀ½-inch octagonal back box, 4-inch octagonal  
back box, Single gang back box, 4-inch square  
back box with a plaster ring, Direct mount to  
ceiling  
Ordering Information  
Model  
Thermal  
Wiring  
Alarm Current  
Model  
Description  
2WTA-B  
Yes  
2-wire  
1ꢀ0 mA max. limited by  
control panel  
RRS-MOD  
2W-MOD2  
SENS-RDR  
RT  
Reversing relay/synchronization module  
2-wire loop test/maintenance module  
Sensitivity reader  
2WTR-B  
Yes  
2-wire  
1ꢀ0 mA max. limited by  
control panel  
Removal/replacement tool  
Retrofit adapter bracket  
4WTA-B  
4WTR-B  
4WTAR-B  
4WITAR-B  
Yes  
Yes  
Yes  
Yes  
4-wire  
4-wire  
4-wire  
4-wire  
ꢀ5 mA  
ꢀ5 mA  
50 mA  
50 mA  
A77-AB2  
©2006 System Sensor.  
ꢀ825 Ohio Avenue • St. Charles, IL 60174  
Phone: 800-SENSOR2 • Fax: 6ꢀ0-ꢀ77-6495  
Product specifications subject to change without notice. Visit systemsensor.com for  
current product information, including the latest version of this data sheet.  
A05-0ꢀ48-00ꢀ • 7/06 • #1676  
厂商 型号 描述 页数 下载

SYSTEMSENSOR

4WT-B 光电感烟探测器[ Photoelectric Smoke Detectors ] 2 页

SYSTEMSENSOR

4WTA-B 烟雾探测器用探测仪和继电器选项[ Smoke Detectors with Sounder and Relay Option ] 2 页

SYSTEMSENSOR

4WTAR-B 烟雾探测器用探测仪和继电器选项[ Smoke Detectors with Sounder and Relay Option ] 2 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.204960s