User's Guide  
EzFlex™ Thermo-Anemometer  
Model EZ30  
˚
˚
VEL  
MAX MIN AVG  
UNITS  
Introduction  
Congratulations on your purchase of the Extech EZ30 Thermo-Anemometer. The EZ30  
measures air velocity in five units of measure: feet per minute (ft/min), meters per  
second (m/sec), miles per hour (MPH), kilometers per hour (km/hr), & nautical miles per  
hour (knots). An internal Type K sensor allows the EZ30 to measure air temperature in  
Celsius or Fahrenheit units. The 16” (406mm) flexible gooseneck provides easy access  
for air velocity and temperature measurement in difficult to reach locations. This meter is  
shipped fully tested and calibrated and with proper use will provide years of reliable  
service.  
Meter Description  
1. LCD display  
2. Vane sensor  
3. Hold/Backlight key  
4. Units/°F/°C key  
5. Max/Min key  
1
3
2
˚
˚
VEL  
6. On/Off key  
MAX MIN AVG  
Note: Battery compartment is on rear of unit  
6
5
UNITS  
4
Display  
1. MAX MIN Record mode  
2. Temperature display  
3. Temperature display  
4. Velocity units  
2
1
3
˚
˚
8
7
VEL  
5. Hold mode  
4
6. MAX or MIN mode  
7. Velocity display  
MAX MIN  
8. Low battery indicator  
6
5
2
Model EZ30 Version 1.1 04/06  
Operation  
Meter Power  
1. Press the POWER button to turn the meter on. If the display does not switch on, check  
that a fresh 9V battery is installed.  
2. Press the POWER button to turn the meter off.  
3. The meter is equipped with an AUTO POWER OFF feature. The meter automatically  
shuts off after 15 minutes to conserve battery energy. To disable this feature, hold  
down the UNITS key while turning the meter on. “disAPO” will appear in the display to  
indicate that Auto Power Off has been disabled.  
Measuring Air Velocity and Temperature  
1. Place the sensor in the air stream under test.  
2. Read the Air Velocity and Temperature measurements directly on the LCD.  
3. To calculate Air Volume in CFM (cubic feet per minute) or CMM (cubic meters per  
minute) refer to the ‘Useful Equations and Conversions’ section.  
Selecting the Temperature unit of measure (oC/oF)  
Press and hold the UNITS key for 3 seconds to select the temperature unit of measure.  
The meter will beep twice and the display will indicate the currently selected unit of  
measure.  
Selecting the Air Velocity unit of measure  
Press the UNITS key to change the unit of measure for Air Velocity measurements. The  
display will reflect the current selection. A list of measurement units is printed in the  
specifications later in this manual.  
Data Hold/Backlight  
To freeze the LCD display, momentarily press the HOLD key. The 'HOLD' icon will appear  
on the LCD and the reading will remain unchanged. Momentarily press the HOLD button  
again to return to normal operation (the 'HOLD' icon will switch off).  
Press and hold the key for 3 seconds to turn the backlight on/off.  
Record and Recall MAX / Min Function  
1. To begin capturing the Maximum (MAX) and Minimum (MIN) air velocity and  
temperature readings, press the MAX/MIN key and the ‘RECORD’ icon will appear in  
the display.  
2. Now, use the MAX/MIN key to toggle the view from MIN to MAX to RECORD. The  
‘MAX’ or ‘MIN’ will appear along with the recalled reading for convenience. In RECORD  
mode, the meter will display the current reading but will continue to capture MAX and  
MIN readings.  
3. To return to normal operation, press and hold the MAX/MIN key for 3 seconds to clear  
and stop MAX/MIN recording. The meter will beep twice and the ‘MAX’/‘MIN’ and  
‘RECORD’ icons will switch off.  
3
Model EZ30 Version 1.1 04/06  
Maintenance  
Battery Replacement  
When the battery power falls low, the low battery icon  
will appear on the LCD. Replace  
the 9V battery by removing the Phillips screw on the battery compartment door and  
accessing the battery compartment. Ensure that the compartment cover is securely  
fastened when finished.  
Cleaning and Storage  
Wipe the meter and vane with a damp cloth as needed. Do not apply abrasive, solvents, or  
other cleaners to the surface of the meter or vane. Store with the battery removed and  
avoid extreme temperature and humidity.  
Specifications  
Circuit description  
Display  
Custom LSI microprocessor design  
Dual function 9999 count LCD display  
m/s, km/h, ft/min, knots , mph, Temperature: oC/oF  
Freezes reading on the display  
Measurement units  
Data hold  
Sensor Structure  
Air velocity sensor: Conventional twisted vane arm with low-  
friction ball-bearing  
Temperature sensor: Type K  
Memory Recall  
Auto Power off  
Record and Recall Maximum/Minimum (MAX/MIN) readings  
After 15 minutes with disable feature  
Operating Temperature 32 °F to 122 °F (0 °C to 50 °C)  
Operating Humidity  
Power Supply  
Power Consumption  
Weight  
Max. 80% RH  
9V battery  
Approx. 8.3mA DC  
7.4 oz (210g)  
Dimensions  
Main instrument: 6.42 x 1.77 x1.34” (163 x 45 x 34mm)  
Sensor Head: 0.7” (17.8 mm) diameter  
Air Velocity Range Specifications  
Measurement  
Range  
Resolution  
Accuracy  
(% of reading)  
ft/min (feet per minute)  
m/s (meters per second)  
km/h (kilometers per hour)  
80 - 5900 ft/min 1 ft/min  
0.40 - 30.00 m/s 0.01 m/s  
1.4 - 108.0 km/h 0.1 km/h  
± (3% + 40 ft/min)  
± (3% + 0.20 m/sec)  
± (3% + 0.8 km/hr)  
± (3% + 0.4 mph)  
± (3% + 0.4 knots)  
mph (miles per hour)  
0.9 - 67.0 mph  
0.1 mph  
knots (nautical miles per hour) 0.8 - 58.0 knots  
Temperature Range Specifications  
0.1 knots  
Range  
Resolution  
Accuracy  
32oF to 122oF (0oC to 50oC)  
0.1oF (0.1oC)  
± 4.0oF (2oC)  
4
Model EZ30 Version 1.1 04/06  
Useful Equations and Conversions  
Volume Measurements  
To determine CFM (cubic feet per minute) or CMM (cubic meters per minute) in a duct, the  
area of the duct must first be measured (use the equations below). Then multiply an air  
velocity measurement by the area measurement to obtain CFM or CMM.  
Area equation for rectangular or square ducts  
Height (H)  
Width (W)  
Area (A) = Width (W) x Height (H)  
Area equation for circular ducts  
Area (A) = x r2  
Radius  
Where = 3.14 and r2 = radius x radius  
Cubic equations  
CFM (ft3/min) = Air Velocity (ft/min) x Area (ft2)  
CMM (m3/min) = Air Velocity (m/sec) x Area (m2) x 60  
NOTE: Measurements made in inches  
must be converted to feet or meters before using the above formulae.  
Unit of Measure Conversion Table  
m/s ft/min  
knots  
1.944  
0.00987  
1
km/h  
3.6  
MPH  
2.24  
1 m/s  
1
196.87  
1
1 ft/min  
1 knot  
1 km/h  
1 MPH  
0.00508  
0.5144  
0.2778  
0.4464  
0.01829  
1.8519  
1
0.01138  
1.1523  
0.6222  
1
101.27  
54.69  
87.89  
0.54  
0.8679  
1.6071  
5
Model EZ30 Version 1.1 04/06  
Warranty  
EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects  
in parts and workmanship for one year from date of shipment (a six month limited warranty  
applies on sensors and cables). If it should become necessary to return the instrument for  
service during or beyond the warranty period, contact the Customer Service Department at  
(781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com for  
contact information. A Return Authorization (RA) number must be issued before any  
product is returned to Extech. The sender is responsible for shipping charges, freight,  
insurance and proper packaging to prevent damage in transit. This warranty does not  
apply to defects resulting from action of the user such as misuse, improper wiring,  
operation outside of specification, improper maintenance or repair, or unauthorized  
modification. Extech specifically disclaims any implied warranties or merchantability or  
fitness for a specific purpose and will not be liable for any direct, indirect, incidental or  
consequential damages. Extech's total liability is limited to repair or replacement of the  
product. The warranty set forth above is inclusive and no other warranty, whether written or  
oral, is expressed or implied.  
Calibration and Repair Services  
Extech offers repair and calibration services for the products we sell. Extech also provides  
NIST certification for most products. Call the Customer Service Department for information  
on calibration services available for this product. Extech recommends that annual  
calibrations be performed to verify meter performance and accuracy.  
Support Hotline (781) 890-7440  
Tech support: Ext. 200; Email: support@extech.com  
Repair/Returns: Ext. 210; Email: repair@extech.com  
Product specifications subject to change without notice  
For the latest version of this User’s Guide, Software updates, and other  
up-to-the-minute product information, visit our website: www.extech.com  
Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451  
Copyright © 2006 Extech Instruments Corporation  
All rights reserved including the right of reproduction in whole or in part in any form.  
6
Model EZ30 Version 1.1 04/06  
厂商 型号 描述 页数 下载

EPCOS

EZ3-A230X 避雷器3电极避雷器[ Surge arrester 3-electrode arrester ] 4 页

EPCOS

EZ3-A230XF1 避雷器3电极避雷器[ Surge arrester 3-electrode arrester ] 4 页

EPCOS

EZ3-A250X 避雷器3电极避雷器[ Surge arrester 3-electrode arrester ] 4 页

EPCOS

EZ3-A250XF1 避雷器3电极避雷器[ Surge arrester 3-electrode arrester ] 4 页

EPCOS

EZ3-A350XF1 避雷器3电极避雷器[ Surge arrester 3-electrode arrester ] 4 页

EPCOS

EZ3-A90X 避雷器3电极避雷器[ Surge arrester 3-electrode arrester ] 4 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.226606s