Inductive sensors
Inductive linear sensors
IWRM 18 (Dist. 2...4 mm / 2...5 mm)
sample drawing
M18x 1
SW 24
general data
sample picture
mounting type
flush
measuring speed
repeat accuracy
temperature coefficient
< 1 mm / ms
< 0,02 mm
1 µm / (K mm)
electrical data
voltage supply range +Vs
residual output ripple
short circuit protection
reverse polarity protection
voltage output
15 ... 30 VDC
< 0,5 % Vs
yes
yes
current consumption max. (no load)
output signal
20 mA
1 ... 9 VDC
> 1000 Ohm
load resistance
current output
current consumption max. (no load)
output signal
35 mA
4 ... 20 mA
< 500 Ohm
< 1000 Ohm
load resistance +Vs min.
load resistance +Vs max.
mechanical data
type
cylindrical threaded
brass nickel plated
18 mm
housing material
dimension
connection types
cable, 2 m
ambient conditions
operating temperature
protection class
0 ... +60 °C
IP 67
1
9/1/2014
www.baumer.com