Inductive sensors
Inductive linear sensors
IWRM 30 (dist. 5...10 mm)
sample drawing
M30x 1,5
SW 36
general data
sample picture
mounting type
flush
measuring speed
repeat accuracy
temperature coefficient
< 1,5 mm / ms
< 0,02 mm
1 µm / (K mm)
electrical data
voltage supply range +Vs
residual output ripple
short circuit protection
reverse polarity protection
voltage output
15 ... 30 VDC
< 0,5 % Vs
yes
yes
current consumption max. (no load)
output signal
20 mA
1 ... 9 VDC
> 1000 Ohm
load resistance
current output
current consumption max. (no load)
output signal
35 mA
4 ... 20 mA
< 500 Ohm
< 1000 Ohm
load resistance +Vs min.
load resistance +Vs max.
mechanical data
type
cylindrical threaded
brass nickel plated
30 mm
housing material
dimension
housing length
connection types
60 mm
cable, 2 m
ambient conditions
operating temperature
protection class
0 ... +60 °C
IP 67
order reference
IWRM 30I9501
IWRM 30U9501
IWRM 30U9502
measuring distance Sd
reference distance
output circuit
current output
voltage output
voltage output
linearity error
200 µm
5 ... 10 mm
5 ... 10 mm
5 ... 9 mm
7,1 ... 7,9 mm
7,1 ... 7,9 mm
6,7 ... 7,3 mm
200 µm
150 µm
1
9/1/2014